Skip to main content
Menu
CVEs

Siemens Mendix OIDC Provider session hijack via JWT introspection endpoint

Affects Mendix OIDC Provider before V4.3.0 (Mendix 9 compatible) and before V6.0.0 (Mendix 10 and 11 compatible). Fixed in V6.0.0.

CVE-2026-124981EUVD-2026-137229GHSA-JHQQ-R4P8-HFFJPublished November 27, 2026, updated

8.7HighCNA
Exploited
No known exploitation
Fix
Fixed in V6.0.0, V4.3.0
Who is exposed
Not reported

Summary

The Siemens Mendix OIDC Provider does not properly validate the integrity of JWTs sent to its token introspection endpoint, so tokens can be matched to legitimate token records based only on their jti value. Remote attackers without logging in could hijack an account session by obtaining the jti of an active token.

Written by a model

Original description

A vulnerability has been identified in Mendix OIDC Provider (Mendix 10 compatible) (All versions < V6.0.0), Mendix OIDC Provider (Mendix 11 compatible) (All versions < V6.0.0), Mendix OIDC Provider (Mendix 9 compatible) (All versions < V4.3.0). Affected versions of the module do not properly validate the integrity of JWTs submitted to the OIDC Provider Token Introspection endpoint, allowing tokens to be associated with legitimate token records based solely on their jti value.

This could allow unauthenticated remote attackers to hijack an account (session) when gaining access to an jti of an active token.

Who should check

Teams running the Siemens Mendix OIDC Provider module (Mendix 9, 10 or 11 compatible) on versions below V4.3.0 or V6.0.0, and their Resource Servers that accept JWTs

“Mendix OIDC Provider (Mendix 10 compatible)”

cert-portal.siemens.com

What to do

  1. Upgrade to a fixed version: V6.0.0, V4.3.0.

  2. Workaround: Ensure that Resource Servers independently validate the cryptographic signature of incoming JWTs before accepting them, rather than relying solely on the OIDC Provider's Token Introspection endpoint.

Check your systems with an agent

Paste this into a coding or ops agent. It checks your systems read-only and reports a table per asset.

Check whether my systems are affected by CVE-2026-124981 (A vulnerability has been identified in Mendix OIDC Provider (Mendix 10 compatible) (All versions < V6.0.0), Mendix OIDC Provider (Mendix…), using the cve.now data below.

Rules: work read-only. Do not run exploit code, proof-of-concept scripts or scanners that send attack payloads, and do not change any configuration, package, image or deployment. Report findings only.

What cve.now has for CVE-2026-124981 (entry last updated 2026-11-27):
Affected:
- Siemens Mendix OIDC Provider (Mendix 10 compatible): fixed in V6.0.0
- Siemens Mendix OIDC Provider (Mendix 11 compatible): fixed in V6.0.0
- Siemens Mendix OIDC Provider (Mendix 9 compatible): fixed in V4.3.0
Fixed versions: V6.0.0, V4.3.0.
Conditions (all must be true for the bug to be hit):
- Mendix OIDC Provider (Mendix 9 compatible) before V4.3.0 (source: https://cert-portal.siemens.com/productcert/html/ssa-545865.html)
- Mendix OIDC Provider (Mendix 10 or 11 compatible) before V6.0.0 (source: https://cert-portal.siemens.com/productcert/html/ssa-545865.html)
- Attacker-supplied JWTs are submitted to the OIDC Provider Token Introspection endpoint (source: https://cert-portal.siemens.com/productcert/html/ssa-545865.html)
Setup: unknown whether the bug needs a non-default feature or setting. Check the advisory.
Attacker needs: network access, no login, no user action.
Workaround: Ensure that Resource Servers independently validate the cryptographic signature of incoming JWTs before accepting them, rather than relying solely on the OIDC Provider's Token Introspection endpoint. (source: https://cert-portal.siemens.com/productcert/html/ssa-545865.html)
CISA KEV: CVE-2026-124981 is not listed as of cve.now's last read.
This KEV status is for CVE-2026-124981 only. If you also check another CVE, look up its own KEV status; never assume it from this one.

How to check:
- Installed software: check what is actually running, not what a repo declares. Read the version from each host, container image and Kubernetes node (the binary's version output, the OS package database, image layers), and check whether the conditions above hold there. Distribution packages may carry a backported fix under an older version number; confirm against the distribution's own advisory.

Verify against the linked advisories before concluding, and cite the date you read each one:
- https://cert-portal.siemens.com/productcert/html/ssa-545865.html
Do not conclude an asset is unaffected unless you checked it and the evidence covers both its version and the conditions above. If you could not check something, mark it unknown and say what is missing.

Report a table with one row per asset and these columns: Asset | Version or build | Status (affected, fixed, not applicable, unknown) | Compensating controls | Exposure (internet-facing, internal, none) | Evidence | Next action.

Entry: https://cve.now/CVE-2026-124981
For follow-up questions, use the cve.now MCP server at https://mcp.cve.now/mcp (no authentication), for example execute with name cve.get and arguments {"id": "CVE-2026-124981"}.

Affected versions

cve.now Index

27Pof 100 · provisional · methodology v3
  • Exploitation0/40No signal
  • Exposure17/25No login or user action needed, reachable over the network without a login · Unknown: Advisories don't say whether default setups are affected
  • Reach?/20Unknown. No tracked technology or package matched
  • Severity9.7/10CVSS 8.7, total technical impact per CISA
  • No patch0/5No signal

What would change the score

  • Would score about 72 if added to CISA KEV
  • Would score about 67 if CISA's SSVC rates exploitation active
  • Would score about 32 if advisories confirm default setups are exposed

Timeline

  1. CVE published
  2. First seen by cve.now
  3. CISA SSVC assessment

    Exploitation: none · Automatable: no · Technical impact: total

  4. Record last updated

Evidence 3

KindSource
Vendor advisory 1Establishes: Affected and fixed versions.
Linkcert-portal.siemens.com · productcert/html/ssa-545865.html
CVE record 2Establishes: The identifier and description.
RecordCVE List · CVE-2026-124981
RecordNVD · CVE-2026-124981

Questions about CVE-2026-124981

Is CVE-2026-124981 being exploited?

It is not in CISA's Known Exploited Vulnerabilities catalog, and CISA's SSVC assessment does not mark exploitation as active. That does not mean it has not been attacked: vendors and researchers can report attacks before CISA lists them. No public exploit code is tracked.

Source: cve.now feed data

What does this mean?

Attacker-supplied JWTs can be submitted to the OIDC Provider Token Introspection endpoint, which allows an unauthenticated remote attacker who obtains the jti of an active token to hijack an account or session.

Source: cert-portal.siemens.com

Which versions are affected by CVE-2026-124981?

Mendix OIDC Provider (Mendix 10 compatible): before V6.0.0. Mendix OIDC Provider (Mendix 11 compatible): before V6.0.0. Mendix OIDC Provider (Mendix 9 compatible): before V4.3.0.

Source: cve.now feed data

Am I affected, and how do I check?

The affected versions are Mendix OIDC Provider builds before V4.3.0 for Mendix 9 compatible and before V6.0.0 for Mendix 10 and 11 compatible. Compare the installed OIDC Provider version against these ranges.

Source: cert-portal.siemens.com

How do I fix CVE-2026-124981?

Update to V6.0.0 or later. Until then, the vendor's workaround is to have Resource Servers independently validate the cryptographic signature of incoming JWTs instead of relying solely on the Token Introspection endpoint.

Source: cert-portal.siemens.com

No corrections so far. Something wrong on this page? Report an error.