ABB authorization bypass via undocumented factory accounts

CVE-2026-4642Published November 27, 2026, updated

6.6MediumCNA
Exploited
No known exploitation
Fix
See vendor advisory
Who is exposed
Not reported

Summary

Undocumented factory accounts in ABB Relion Protection Relays, including the REX610, RE_611 IEC/CN, RBX615, REF615, RER615, REC615, and REX615 models, and the ABB Substation Merging Unit SMU615, can let an attacker gain unauthorized access. An attacker can reach these devices over the network, but they must already hold high-privilege login credentials, and no user action is needed.

Written by a model

Original description

Incorrect Authorization vulnerability in ABB Relion Protection Relays REX610, ABB Relion Protection Relays RE_611 IEC/CN, ABB Relion Protection Relays RBX615, ABB Relion Protection Relays REF615 ANSI, ABB Relion Protection Relays REF615R ANSI, ABB Relion Protection Relays RER615, ABB Relion Protection Relays REC615, ABB Relion Protection Relays REX615, ABB Relion Protection Relays 615 series IEC, ABB Relion Protection Relays 615 series CN, ABB Relion Protection Relays 615 series ANSI, ABB Relion Protection Relays RER620 ANSI, ABB Relion Protection Relays 620 series ANSI, ABB Relion Protection Relays 620 series IEC/CN, and ABB Substation Merging Unit SMU615.

This issue affects Relion Protection Relays REX610: 1.0, 1.1, and 1.2; Relion Protection Relays RE_611 IEC/CN: 1.0 and 2.0; Relion Protection Relays RBX615: 1.0 and 2.0; Relion Protection Relays REF615 ANSI: 4.1; Relion Protection Relays REF615R ANSI: 4.0 and 4.0 FP1; Relion Protection Relays RER615: 1.0, 1.1, and 2.0; Relion Protection Relays REC615: 1.0, 1.1, and 2.0; Relion Protection Relays REX615: PCL1 (6.0); Relion Protection Relays 615 series IEC: 3.1, 4.0, 4.0 FP1, 5.0, and 5.0 FP1; Relion Protection Relays 615 series CN: 3.1, 4.1, and 5.0 FP1; Relion Protection Relays 615 series ANSI: 4.0, 4.0 FP1, 4.0 FP2, and 5.0 FP1; Relion Protection Relays RER620 ANSI: 1.1, 1.2, and 1.3; Relion Protection Relays 620 series ANSI: 2.0 and 2.0 FP1; Relion Protection Relays 620 series IEC/CN: 2.0 and 2.0 FP1; Substation Merging Unit SMU615: 1.0.

What to do

Check your systems with an agent

Paste this into a coding or ops agent. It checks your systems read-only and reports a table per asset.

Check whether my systems are affected by CVE-2026-4642 (Undocumented factory accounts), using the cve.now data below.

Rules: work read-only. Do not run exploit code, proof-of-concept scripts or scanners that send attack payloads, and do not change any configuration, package, image or deployment. Report findings only.

What cve.now has for CVE-2026-4642 (entry last updated 2026-11-27):
Affected:
- ABB Relion Protection Relays REX610: versions 1.0, 1.1, 1.2
- ABB Relion Protection Relays RE_611 IEC/CN: versions 1.0, 2.0
- ABB Relion Protection Relays RBX615: versions 1.0, 2.0
- ABB Relion Protection Relays REF615 ANSI: versions 4.1
- ABB Relion Protection Relays REF615R ANSI: versions 4.0, 4.0 FP1
- ABB Relion Protection Relays RER615: versions 1.0, 1.1, 2.0
- ABB Relion Protection Relays REC615: versions 1.0, 1.1, 2.0
- ABB Relion Protection Relays REX615: versions PCL1 (6.0)
- ABB Relion Protection Relays 615 series IEC: versions 3.1, 4.0, 4.0 FP1, 5.0, 5.0 FP1
- ABB Relion Protection Relays 615 series CN: versions 3.1, 4.1, 5.0 FP1
- and 5 more affected products, listed on https://cve.now/CVE-2026-4642
Fixed versions: none listed yet.
Setup: unknown whether the bug needs a non-default feature or setting. Check the advisory.
CISA KEV: CVE-2026-4642 is not listed as of cve.now's last read.
This KEV status is for CVE-2026-4642 only. If you also check another CVE, look up its own KEV status; never assume it from this one.

How to check:
- Installed software: check what is actually running, not what a repo declares. Read the version from each host, container image and Kubernetes node (the binary's version output, the OS package database, image layers), and check whether the conditions above hold there. Distribution packages may carry a backported fix under an older version number; confirm against the distribution's own advisory.

Verify against the linked advisories before concluding, and cite the date you read each one:
- https://search.abb.com/library/Download.aspx?DocumentID=2NGA002995&LanguageCode=en&DocumentPartId=pdf&Action=Launch
Do not conclude an asset is unaffected unless you checked it and the evidence covers both its version and the conditions above. If you could not check something, mark it unknown and say what is missing.

Report a table with one row per asset and these columns: Asset | Version or build | Status (affected, fixed, not applicable, unknown) | Compensating controls | Exposure (internet-facing, internal, none) | Evidence | Next action.

Entry: https://cve.now/CVE-2026-4642
For follow-up questions, use the cve.now MCP server at https://mcp.cve.now/mcp (no authentication), for example execute with name cve.get and arguments {"id": "CVE-2026-4642"}.

Affected versions

cve.now Index

15Pof 100 · provisional · methodology v3
  • Exploitation?/40Unknown. No CISA SSVC exploitation rating yet
  • Exposure3/25Reachable over the network · Unknown: No advisory context yet
  • Reach?/20Unknown. No tracked technology or package matched
  • Severity6.6/10CVSS 6.6
  • No patch5/5No fixed version listed; see vendor advisory

What would change the score

  • Would score about 70 if added to CISA KEV
  • Would score about 65 if CISA's SSVC rates exploitation active
  • Would score about 34 if advisories confirm default setups are exposed

Timeline

  1. CVE published
  2. First seen by cve.now

Evidence 3

KindSource
Vendor advisory 1Establishes: Affected and fixed versions.
Linksearch.abb.com · library/Download.aspx?DocumentID=2NGA002995&LanguageCode=en&DocumentPartId=pdf&Action=Launch
CVE record 2Establishes: The identifier and description.
RecordCVE List · CVE-2026-4642
RecordNVD · CVE-2026-4642

Questions about CVE-2026-4642

Is CVE-2026-4642 being exploited?

It is not in CISA's Known Exploited Vulnerabilities catalog, and CISA's SSVC assessment does not mark exploitation as active. That does not mean it has not been attacked: vendors and researchers can report attacks before CISA lists them. No public exploit code is tracked.

Source: cve.now feed data

Which versions are affected by CVE-2026-4642?

Relion Protection Relays REX610: versions 1.0, 1.1, 1.2. Relion Protection Relays RE_611 IEC/CN: versions 1.0, 2.0. Relion Protection Relays RBX615: versions 1.0, 2.0. Relion Protection Relays REF615 ANSI: version 4.1. Relion Protection Relays REF615R ANSI: versions 4.0, 4.0 FP1. 10 more packages are listed on the page.

Source: cve.now feed data

No corrections so far. Something wrong on this page? Report an error.