Skip to main content
← Vulnerabilities

Module Manager loaders leave the manager mutex held when a module preamble's sizes overflow, blocking every later module operation

Only ThreadX 6.0.1 through 6.5.2.202603 systems that use the Module Manager and load module images through the in-place, memory, absolute or absolute extended loaders are covered. Fixed in 6.5.2.202603b.

Written by anthropic/claude-haiku-5.5 from the sources below. Verify against them.

6.8MediumCNA
Exploited
No known exploitation
Fix
Fixed in 6.5.2.202603b
Who is exposed
Specific setups only

Do first: Check whether your setup matches what the bug needs. Systems that use the Module Manager and load module images through the in-place, memory, absolute or absolute extended loaders Affected ThreadX versions are 6.0.1 through 6.5.2.202603

Published
Last modified
Published
Not listed in CISA KEV
12/100 · provisional
Specific setups only
Fix
Fixed in 6.5.2.202603b
None on Exploit-DB, Metasploit or GitHub
  • Exploitation: none
  • Automatable: no
  • Technical impact: partial

Summary

Eclipse ThreadX, a real-time operating system used in embedded devices, is affected. A malformed module image with oversized data or stack size values can cause the Module Manager to stop releasing its internal lock, so every later module load, start, stop, or unload hangs until the device is reset.

Read the original description

In Eclipse ThreadX versions 6.0.1 through 6.5.2.202603, the Module Manager loaders return an overflow error without releasing the Module Manager mutex when a module preamble declares a data or stack size that overflows the allocation arithmetic. Loading such an image blocks every later module load, start, stop and unload from other threads until the system is reset.

What to do

  • Check whether your setup matches what the bug needs.

    Systems that use the Module Manager and load module images through the in-place, memory, absolute or absolute extended loaders Affected ThreadX versions are 6.0.1 through 6.5.2.202603
  • Upgrade to a fixed version: 6.5.2.202603b.

Timeline

  1. CVE published
  2. First seen by cve.now
  3. CISA SSVC assessment

    Exploitation: none · Automatable: no · Technical impact: partial

  4. Record last updated

Affected versions

  • Eclipse Foundation Eclipse ThreadX

    From 6.0.1 · through 6.5.2.202603

Evidence 2

  1. Advisory
  2. Link

Corrections

None so far.

Something wrong on this page? Report an error. Every fix is listed here.

FAQ

Questions about CVE-2026-118052

What does this mean?

A module image with an oversized data or stack size makes the Module Manager loader leave its manager mutex held. Every other thread is then blocked from loading, starting, stopping or unloading modules until the system is reset.Source: github.com

Am I affected, and how do I check?

ThreadX versions 6.0.1 through 6.5.2.202603 are in the affected range, but only for systems that use the Module Manager and load module images through the in-place, memory, absolute or absolute extended loaders. To check, confirm the ThreadX version in use and whether the module loading path uses one of those loaders.Source: github.com

What should I do about it?

Upgrade to ThreadX 6.5.2.202603b, which contains the fix. The facts provided do not list a workaround.Source: github.com

Is it being exploited?

It is not in CISA's Known Exploited Vulnerabilities catalog, and CISA's SSVC assessment does not mark exploitation as active. That does not mean it has not been attacked: vendors and researchers can report attacks before CISA lists them. No public exploit code is tracked.Source: cve.now feed data