# CVEs published 2015-08-04

32 CVEs were published on August 4, 2015: 0 critical, 0 high. Days are UTC.

- [CVE-2001-1594](https://cve.now/CVE-2001-1594.md): GE Healthcare eNTEGRA P&R has a password of (1) entegra for the entegra user, (2) passme for the super user of the Polestar/Polestar-i Starl (no CVSS)
- [CVE-2002-2445](https://cve.now/CVE-2002-2445.md): GE Healthcare Millennium MG, NC, and MyoSIGHT has a default password of (1) root.genie for the root user, (2) "service." for the service use (no CVSS)
- [CVE-2002-2446](https://cve.now/CVE-2002-2446.md): GE Healthcare Millennium MG, NC, and MyoSIGHT has a password of insite.genieacq for the insite account that cannot be changed without disabl (no CVSS)
- [CVE-2003-1603](https://cve.now/CVE-2003-1603.md): GE Healthcare Discovery VH has a default password of (1) interfile for the ftpclient user of the Interfile server or (2) "2" for the LOCAL u (no CVSS)
- [CVE-2004-2777](https://cve.now/CVE-2004-2777.md): GE Healthcare Centricity Image Vault 3.x has a password of (1) gemnet for the administrator account, (2) webadmin for the webadmin administr (no CVSS)
- [CVE-2006-7253](https://cve.now/CVE-2006-7253.md): GE Healthcare Infinia II has a default password of (1) infinia for the infinia user, (2) #bigguy1 for the acqservice user, (3) dont4get2 for (no CVSS)
- [CVE-2007-6757](https://cve.now/CVE-2007-6757.md): GE Healthcare Centricity DMS 4.2, 4.1, and 4.0 has a password of Muse!Admin for the Museadmin user, which has unspecified impact and attack (no CVSS)
- [CVE-2009-5143](https://cve.now/CVE-2009-5143.md): GE Healthcare Discovery 530C has a password of #bigguy1 for the (1) acqservice user and (2) wsservice user of the Xeleris System, which has (no CVSS)
- [CVE-2010-5306](https://cve.now/CVE-2010-5306.md): GE Healthcare Optima CT680, CT540, CT640, and CT520 has a default password of #bigguy for the root user, which has unspecified impact and at (no CVSS)
- [CVE-2010-5307](https://cve.now/CVE-2010-5307.md): The HIPAA configuration interface in GE Healthcare Optima MR360 has a password of (1) operator for the root account, (2) adw2.0 for the admi (no CVSS)
- [CVE-2010-5308](https://cve.now/CVE-2010-5308.md): GE Healthcare Optima MR360 does not require authentication for the HIPAA emergency login procedure, which allows physically proximate users (no CVSS)
- [CVE-2010-5309](https://cve.now/CVE-2010-5309.md): GE Healthcare CADStream Server has a default password of confirma for the admin user, which has unspecified impact and attack vectors. (no CVSS)
- [CVE-2010-5310](https://cve.now/CVE-2010-5310.md): The Acquisition Workstation for the GE Healthcare Revolution XQ/i has a password of adw3.1 for the sdc user, which has unspecified impact an (no CVSS)
- [CVE-2011-5322](https://cve.now/CVE-2011-5322.md): GE Healthcare Centricity Analytics Server 1.1 has a default password of (1) V0yag3r for the SQL Server sa user, (2) G3car3s for the analyst (no CVSS)
- [CVE-2011-5323](https://cve.now/CVE-2011-5323.md): GE Healthcare Centricity PACS-IW 3.7.3.7, 3.7.3.8, and possibly other versions has a password of A11enda1e for the sa SQL server user, which (no CVSS)
- [CVE-2011-5324](https://cve.now/CVE-2011-5324.md): The TeraRecon server, as used in GE Healthcare Centricity PACS-IW 3.7.3.7, 3.7.3.8, and possibly other versions, has a password of (1) share (no CVSS)
- [CVE-2012-6660](https://cve.now/CVE-2012-6660.md): GE Healthcare Precision MPi has a password of (1) orion for the serviceapp user, (2) orion for the clinical operator user, and (3) PlatinumO (no CVSS)
- [CVE-2012-6693](https://cve.now/CVE-2012-6693.md): GE Healthcare Centricity PACS 4.0 Server has a default password of (1) nasro for the nasro (ReadOnly) user and (2) nasrw for the nasrw (Read (no CVSS)
- [CVE-2012-6694](https://cve.now/CVE-2012-6694.md): GE Healthcare Centricity PACS Workstation 4.0 and 4.0.1, and Server 4.0, has a password of 2charGE for the geservice account, which has unsp (no CVSS)
- [CVE-2012-6695](https://cve.now/CVE-2012-6695.md): GE Healthcare Centricity PACS Workstation 4.0 and 4.0.1 has a password of ddpadmin for the ddpadmin user, which has unspecified impact and a (no CVSS)
- [CVE-2013-7404](https://cve.now/CVE-2013-7404.md): GE Healthcare Discovery NM 750b has a password of 2getin for the insite account for (1) Telnet and (2) FTP, which has unspecified impact and (no CVSS)
- [CVE-2013-7405](https://cve.now/CVE-2013-7405.md): The Ad Hoc Reporting feature in GE Healthcare Centricity DMS 4.2 has a password of Never!Mind for the Administrator user, which has unspecif (no CVSS)
- [CVE-2013-7442](https://cve.now/CVE-2013-7442.md): GE Healthcare Centricity PACS Workstation 4.0 and 4.0.1 has a password of (1) CANal1 for the Administrator user and (2) iis for the IIS user (no CVSS)
- [CVE-2014-7232](https://cve.now/CVE-2014-7232.md): GE Healthcare Discovery XR656 and XR656 G2 has a password of (1) 2getin for the insite user, (2) 4$xray for the xruser user, and (3) #superx (no CVSS)
- [CVE-2014-7233](https://cve.now/CVE-2014-7233.md): GE Healthcare Precision THUNIS-800+ has a default password of (1) 1973 for the factory default System Utilities menu, (2) TH8740 for install (no CVSS)
- [CVE-2014-9736](https://cve.now/CVE-2014-9736.md): GE Healthcare Centricity Clinical Archive Audit Trail Repository has a default password of initinit for the (1) SSL key manager and (2) serv (no CVSS)
- [CVE-2015-3940](https://cve.now/CVE-2015-3940.md): Untrusted search path vulnerability in Schneider Electric Wonderware System Platform before 2014 R2 Patch 01 allows local users to gain priv (no CVSS)
- [CVE-2015-3942](https://cve.now/CVE-2015-3942.md): Multiple cross-site scripting (XSS) vulnerabilities in the web-server component in MNS before 4.5.6 on Belden GarrettCom Magnum 6K and Magnu (no CVSS)
- [CVE-2015-3959](https://cve.now/CVE-2015-3959.md): The firmware in MNS before 4.5.6 on Belden GarrettCom Magnum 6K and Magnum 10K switches has a hardcoded serial-console password for a privil (no CVSS)
- [CVE-2015-3960](https://cve.now/CVE-2015-3960.md): The firmware in MNS before 4.5.6 on Belden GarrettCom Magnum 6K and Magnum 10K switches uses hardcoded RSA private keys and certificates acr (no CVSS)
- [CVE-2015-3961](https://cve.now/CVE-2015-3961.md): The web-server component in MNS before 4.5.6 on Belden GarrettCom Magnum 6K and Magnum 10K switches allows remote authenticated users to cau (no CVSS)
- [CVE-2015-3963](https://cve.now/CVE-2015-3963.md): Wind River VxWorks before 5.5.1, 6.5.x through 6.7.x before 6.7.1.1, 6.8.x before 6.8.3, 6.9.x before 6.9.4.4, and 7.x before 7 ipnet\_coreip (no CVSS)

---