Skip to main content
← All vulnerabilities
CVE-2026-9143

Incorrect Conversion between Numeric Types in NI grpc-device due to missing range checks in CodeGen

Published
Last modified
published
Not listed in CISA KEV
None on Exploit-DB, Metasploit or GitHub
  • Exploitation: none
  • Automatable: no
  • Technical impact: partial

Summary

There is an incorrect conversion between numeric types vulnerability in NI grpc-device due to missing range checks in CodeGen.  This may silently discard high bits if a size value exceeded the target type's range. This affects NI grpc-device 2.17.0 and prior versions.

Timeline

  1. CVE published
  2. CISA SSVC assessment

    Exploitation: none · Automatable: no · Technical impact: partial

  3. Record last updated

Affected versions

  • NI grpc-device

    through 2.17.0

  • NI InstrumentStudio

    through 26.3.0

References 2

ni.com

GitHub · ni/grpc-device