Flowintel Organization Administrator Can Reset Full Administrator Password and Escalate Privileges
- Published
- Last modified
- Where the record stands: published, rejected by its publisher, or superseded by another id.What do these mean? →
- published
- Whether CISA lists it in its Known Exploited Vulnerabilities catalog: proof that attackers are using it.What do these mean? →
- Not listed in CISA KEV
- Fix
- Fix or patch referenced
- Whether working attack code is public (Exploit-DB, Metasploit, Nuclei or GitHub). Public code makes attacks easier.What do these mean? →
- None on Exploit-DB, Metasploit or GitHub
- Exploitation: none
- Automatable: no
- Technical impact: total
Summary
Affected versions of Flowintel contain an authorization flaw in the administrative user-edit API. The existing authorization check correctly prevented an organization administrator from editing users in another organization, but it did not prevent them from editing a full administrator within their own organization. As a result, an org admin could modify that full administrator account, including changing its password. The upstream commit explicitly describes the issue as: “Org admin can change the password of a full admin in the same organization.” The fix adds a higher-privilege boundary check: if user_to_edit.is_admin(): return ... 403 so organization administrators can no longer modify full administrator accounts. Version impacted >=3.3.0
Timeline
- CVE published
- CISA SSVC assessment
Exploitation: none · Automatable: no · Technical impact: total
- Record last updated
Affected versions
- flowintel flowintel
through 3.3.0