Lantronix Autonomous Out-of-Band Devices Predictable Session Token with Validation Bypass
- Published
- Last modified
- Where the record stands: published, rejected by its publisher, or superseded by another id.What do these mean? →
- published
- Whether CISA lists it in its Known Exploited Vulnerabilities catalog: proof that attackers are using it.What do these mean? →
- Not listed in CISA KEV
- Whether working attack code is public (Exploit-DB, Metasploit, Nuclei or GitHub). Public code makes attacks easier.What do these mean? →
- None on Exploit-DB, Metasploit or GitHub
- Exploitation: none
- Automatable: no
- Technical impact: total
Summary
All firmware versions of Lantronix SLC8000, SLC9000, EMG8500, EMG7500, SLB882, SLCx-03, and SLCx-02 contain an authentication bypass vulnerability in the web management portal that allows unauthenticated attackers to derive valid session tokens of logged-in users and bypass source IP and User-Agent validation. Session tokens are generated deterministically from the device model and the current time at one-second resolution, resulting in a small enumerable set of possible active tokens. Attackers can construct a crafted URI that exploits file extension handling in the web server path routing to bypass per-session source-address validation, then use a derived token from a different source address to gain elevated privileges on the affected device and potentially impact downstream serial-attached devices.
Timeline
- CVE published
- CISA SSVC assessment
Exploitation: none · Automatable: no · Technical impact: total
- Record last updated
Affected versions
- LANTRONIX SLC8000
*
- LANTRONIX EMG8500
*
- LANTRONIX EMG7500
*
- LANTRONIX SLB882
*
- LANTRONIX SLCx-03
*
- LANTRONIX SLCx-02
*
- LANTRONIX SLC9000
*