CVE-2026-79316
An improper access control vulnerability exists in x-ui 0.3.2.
- Published
- Last modified
- Where the record stands: published, rejected by its publisher, or superseded by another id.What do these mean? →
- published
- Whether CISA lists it in its Known Exploited Vulnerabilities catalog: proof that attackers are using it.What do these mean? →
- Not listed in CISA KEV
- Whether working attack code is public (Exploit-DB, Metasploit, Nuclei or GitHub). Public code makes attacks easier.What do these mean? →
- None on Exploit-DB, Metasploit or GitHub
CISA's decision points: whether it is exploited, whether attacks can be automated, and how much control an attacker gets. Assessed (SSVC 2.0.3).What do these mean? →
- Exploitation: none
- Automatable: no
- Technical impact: partial
Summary
An improper access control vulnerability exists in x-ui 0.3.2. Any authenticated panel user can modify the xray configuration template through the settings interface and trigger a panel restart, causing the xray management gRPC service, which is bound to loopback by default, to be regenerated and bound to non-loopback addresses. This expands the reachable surface of the management interface beyond its intended local-only boundary.
Timeline
- CVE published
- CISA SSVC assessment
Exploitation: none · Automatable: no · Technical impact: partial
- Record last updated
Affected versions
- n/a n/a
Version range not reported