Lack of cryptographic protection in Wertheim SafeController 5400 enables RS-485 message sniffing and replay

Published
Last modified
published
Not listed in CISA KEV
None on Exploit-DB, Metasploit or GitHub
  • Exploitation: poc
  • Automatable: no
  • Technical impact: total

Summary

The Wertheim SafeController 5400, Controller 5400 - AssemblyVersion 6.11.8130.22320, uses RS-485 communication between the server and the microcontroller without cryptographic protection. An attacker with access to the communication path between the server and the microcontroller can sniff RS-485 messages and replay previously observed messages. This can be used, for example, to spoof a "quit alarm" message and continuously deactivate the safe alarm.

Timeline

  1. CVE published
  2. CISA SSVC assessment

    Exploitation: poc · Automatable: no · Technical impact: total

  3. Record last updated

Affected versions

  • Wertheim GmbH Wertheim SafeController 5400 Hardware for VAULT ROOMS (Safe Deposit Locker System - Microcontroller)

    Version range not reported