Skip to main content
← All vulnerabilities
CVE-2026-33790

Junos OS: SRX Series: In a NAT64 configuration, receipt of a specific, malformed ICMPv6 packet will cause the srxpfe process to crash and restart.

Published
Last modified
published
Not listed in CISA KEV
Fix
Fixed in 21.2R3-S10, 21.4R3-S12, 22.2R3-S8, 22.4R3-S9, 23.2R2-S6, and 3 more
None on Exploit-DB, Metasploit or GitHub
  • Exploitation: none
  • Automatable: yes
  • Technical impact: partial

Summary

An Improper Check for Unusual or Exceptional Conditions vulnerability in the flow daemon (flowd) of Juniper Networks Junos OS on SRX Series allows an attacker sending a specific, malformed ICMPv6 packet to cause the srxpfe process to crash and restart. Continued receipt and processing of these packets will repeatedly crash the srxpfe process and sustain the Denial of Service (DoS) condition. During NAT64 translation, receipt of a specific, malformed ICMPv6 packet destined to the device will cause the srxpfe process to crash and restart. This issue cannot be triggered using IPv4 nor other IPv6 traffic. This issue affects Junos OS on SRX Series: • all versions before 21.2R3-S10, • all versions of 21.3, • from 21.4 before 21.4R3-S12, • all versions of 22.1, • from 22.2 before 22.2R3-S8, • all versions of 22.4, • from 22.4 before 22.4R3-S9, • from 23.2 before 23.2R2-S6, • from 23.4 before 23.4R2-S7, • from 24.2 before 24.2R2-S3, • from 24.4 before 24.4R2-S3, • from 25.2 before 25.2R1-S2, 25.2R2.

Timeline

  1. CVE published
  2. CISA SSVC assessment

    Exploitation: none · Automatable: yes · Technical impact: partial

  3. Record last updated

Affected versions

  • Juniper Networks Junos OS

    fixed in 21.2R3-S10; From 21.4 · fixed in 21.4R3-S12; From 22.2 · fixed in 22.2R3-S8; From 22.4 · fixed in 22.4R3-S9; From 23.2 · fixed in 23.2R2-S6; From 23.4 · fixed in 23.4R2-S7; From 24.2 · fixed in 24.2R2-S3; From 24.4 · fixed in 24.4R2-S3; From 21.3; From 22.1; From 22.3

References 1

kb.juniper.net