Skip to main content
← All vulnerabilities
CVE-2026-22105EUVD-2026-113764GHSA-QGX4-4F35-7645

Use of default password based on serial number

Published
Last modified
published
Not listed in CISA KEV
Fix
Fixed in 2.4.18, 4.4.1
None on Exploit-DB, Metasploit or GitHub
  • Exploitation: none
  • Automatable: no
  • Technical impact: total

Summary

The affected products are Delta UFC500 electric vehicle charging stations, whose default Service account password is generated from the device's serial number. An attacker on the same local network could work out this password and log in to view or change sensitive settings, including the connection to the OCPP backend.

Summarized by anthropic/claude-haiku-5.5. Verify details against the original sources.

Read the original description

Delta UFC500 charging stations derive the default credentials of the Service account from character positions of the device serial number. An unauthenticated attacker with adjacent network access can reconstruct the resulting password, or exhaust the keyspace, and log in to read and change sensitive settings such as the OCPP backend.

Timeline

  1. CVE published
  2. First seen by cve.now
  3. CISA SSVC assessment

    Exploitation: none · Automatable: no · Technical impact: total

  4. Record last updated

Affected versions

  • msi-image

    fixed in 2.4.18

  • ECP

    fixed in 4.4.1

References 2

csirt.divd.nl