CVE-2026-100702GHSA-8VVX-RFF5-P5RQ
Nodemailer before 10.0.2 Stack Exhaustion via Nested Recipient Arrays
- Published
- Last modified
- Where the record stands: published, rejected by its publisher, or superseded by another id.What do these mean? →
- published
- Whether CISA lists it in its Known Exploited Vulnerabilities catalog: proof that attackers are using it.What do these mean? →
- Not listed in CISA KEV
- Fix
- Fixed in 10.0.2
- Whether working attack code is public (Exploit-DB, Metasploit, Nuclei or GitHub). Public code makes attacks easier.What do these mean? →
- None on Exploit-DB, Metasploit or GitHub
CISA's decision points: whether it is exploited, whether attacks can be automated, and how much control an attacker gets. Assessed (SSVC 2.0.3).What do these mean? →
- Exploitation: none
- Automatable: no
- Technical impact: partial
Summary
Nodemailer before 10.0.2 fails to properly flatten deeply nested arrays in recipient fields such as to, cc, and bcc, allowing attackers to cause stack exhaustion. Attackers can supply a deeply nested JSON recipient array that triggers recursive Array.toString() conversion, exhausting the call stack and terminating the Node.js process.
Timeline
- CVE published
- CISA SSVC assessment
Exploitation: none · Automatable: no · Technical impact: partial
- Record last updated
Affected versions
- nodemailer nodemailer
fixed in 10.0.2
- nodemailernpm
fixed in 10.0.2