Synway SMG Gateway Management Software OS Command Injection via radius_address

Published
Last modified
published
Not listed in CISA KEV
None on Exploit-DB, Metasploit or GitHub
  • Exploitation: poc
  • Automatable: yes
  • Technical impact: total

Summary

Synway SMG Gateway Management Software contains an OS command injection vulnerability in the RADIUS configuration endpoint at /en/9-2radius.php where the radius_address POST parameter is split and interpolated directly into a sed command without sanitization. An unauthenticated remote attacker can inject arbitrary shell commands by submitting a POST request with crafted radius_address, radius_address2, shared_secret2, source_ip, timeout, or retry parameters along with save=1 and enable_radius=1 to achieve remote code execution. Exploitation evidence was first observed by the Shadowserver Foundation on 2025-07-11 (UTC).

Timeline

  1. CVE published
  2. CISA SSVC assessment

    Exploitation: poc · Automatable: yes · Technical impact: total

  3. Record last updated

Affected versions

  • Synway Information Engineering Co., Ltd. Synway SMG Gateway Management Software