Skip to main content
← All vulnerabilities
CVE-2025-69426

Ruckus vRIoT IoT Controller < 3.0.0.0 Hardcoded SSH Credentials RCE

Published
Last modified
published
Not listed in CISA KEV
Fix
Fixed in 3.0.0.0 (GA)
None on Exploit-DB, Metasploit or GitHub
  • Exploitation: none
  • Automatable: yes
  • Technical impact: total

Summary

The Ruckus vRIoT IoT Controller firmware versions prior to 3.0.0.0 (GA) contain hardcoded credentials for an operating system user account within an initialization script. The SSH service is network-accessible without IP-based restrictions. Although the configuration disables SCP and pseudo-TTY allocation, an attacker can authenticate using the hardcoded credentials and establish SSH local port forwarding to access the Docker socket. By mounting the host filesystem via Docker, an attacker can escape the container and execute arbitrary OS commands as root on the underlying vRIoT controller, resulting in complete system compromise.

Timeline

  1. CVE published
  2. CISA SSVC assessment

    Exploitation: none · Automatable: yes · Technical impact: total

  3. Record last updated

Affected versions

  • RUCKUS Networks vRIoT IOT Controller

    From 2.3.0.0 (GA) · fixed in 3.0.0.0 (GA); From 2.3.1.0 (MR) · fixed in 3.0.0.0 (GA); From 2.4.0.0 (GA) · fixed in 3.0.0.0 (GA)

References 2

support.ruckuswireless.com

vulncheck.com