CVE-2025-57766PYSEC-2026-1348GHSA-RPW8-82V9-3Q87
Fides's Admin UI User Password Change Does Not Invalidate Current Session
- Published
- Last modified
- Where the record stands: published, rejected by its publisher, or superseded by another id.What do these mean? →
- published
- Whether CISA lists it in its Known Exploited Vulnerabilities catalog: proof that attackers are using it.What do these mean? →
- Not listed in CISA KEV
- Fix
- Fixed in 2.69.1
- Whether working attack code is public (Exploit-DB, Metasploit, Nuclei or GitHub). Public code makes attacks easier.What do these mean? →
- None on Exploit-DB, Metasploit or GitHub
CISA's decision points: whether it is exploited, whether attacks can be automated, and how much control an attacker gets. Assessed (SSVC 2.0.3).What do these mean? →
- Exploitation: none
- Automatable: no
- Technical impact: partial
Summary
Fides is an open-source privacy engineering platform. Prior to version 2.69.1, admin UI user password changes in Fides do not invalidate active user sessions, creating a vulnerability chaining opportunity where attackers who have obtained session tokens through other attack vectors (such as XSS) can maintain access even after password reset. This issue is not directly exploitable on its own and requires a prerequisite vulnerability to obtain valid session tokens in the first place. Version 2.69.1 fixes the issue. No known workarounds are available.
Timeline
- CVE published
- CISA SSVC assessment
Exploitation: none · Automatable: no · Technical impact: partial
- Record last updated
Affected versions
- ethyca fides
fixed in 2.69.1
- ethyca-fidesPyPI
fixed in 2.69.1