Junos OS: MX Series: When specific SIP packets are processed the MS-MPC will crash
- Published
- Last modified
- Where the record stands: published, rejected by its publisher, or superseded by another id.What do these mean? →
- published
- Whether CISA lists it in its Known Exploited Vulnerabilities catalog: proof that attackers are using it.What do these mean? →
- Not listed in CISA KEV
- Fix
- Fixed in 21.2R3-S9, 22.2R3-S6, 22.4R3-S6
- Whether working attack code is public (Exploit-DB, Metasploit, Nuclei or GitHub). Public code makes attacks easier.What do these mean? →
- None on Exploit-DB, Metasploit or GitHub
- Exploitation: none
- Automatable: no
- Technical impact: partial
Summary
An Improper Resource Shutdown or Release vulnerability in the SIP ALG of Juniper Networks Junos OS on MX Series with MS-MPC allows an unauthenticated, network-based attacker to cause a Denial-of-Service (DoS). When an MX Series device with an MS-MPC is configured with two or more service sets which are both processing SIP calls, a specific sequence of call events will lead to a crash and restart of the MS-MPC. This issue affects Junos OS: • all versions before 21.2R3-S9, • 21.4 versions from 21.4R1, • 22.2 versions before 22.2R3-S6, • 22.4 versions before 22.4R3-S6. As the MS-MPC is EoL after Junos OS 22.4, later versions are not affected. This issue does not affect MX-SPC3 or SRX Series devices.
Timeline
- CVE published
- CISA SSVC assessment
Exploitation: none · Automatable: no · Technical impact: partial
- Record last updated
Affected versions
- Juniper Networks Junos OS
fixed in 21.2R3-S9; From 21.4; From 22.2 · fixed in 22.2R3-S6; From 22.4 · fixed in 22.4R3-S6