Junos OS: ACX Series: When 'hot-standby' mode is configured for an L2 circuit, interface flap causes the FEB to crash
- Published
- Last modified
- Where the record stands: published, rejected by its publisher, or superseded by another id.What do these mean? →
- published
- Whether CISA lists it in its Known Exploited Vulnerabilities catalog: proof that attackers are using it.What do these mean? →
- Not listed in CISA KEV
- Fix
- Fixed in 21.2R3-S9
- Whether working attack code is public (Exploit-DB, Metasploit, Nuclei or GitHub). Public code makes attacks easier.What do these mean? →
- None on Exploit-DB, Metasploit or GitHub
- Exploitation: none
- Automatable: no
- Technical impact: partial
Summary
An Improper Handling of Exceptional Conditions vulnerability in route processing of Juniper Networks Junos OS on specific end-of-life (EOL) ACX Series platforms allows an attacker to crash the Forwarding Engine Board (FEB) by flapping an interface, leading to a Denial of Service (DoS). On ACX1000, ACX1100, ACX2000, ACX2100, ACX2200, ACX4000, ACX5048, and ACX5096 devices, FEB0 will crash when the primary path port of the L2 circuit IGP (Interior Gateway Protocol) on the local device goes down. This issue is seen only when 'hot-standby' mode is configured for the L2 circuit. This issue affects Junos OS on ACX1000, ACX1100, ACX2000, ACX2100, ACX2200, ACX4000, ACX5048, and ACX5096: • all versions before 21.2R3-S9.
Timeline
- CVE published
- CISA SSVC assessment
Exploitation: none · Automatable: no · Technical impact: partial
- Record last updated
Affected versions
- Juniper Networks Junos OS
fixed in 21.2R3-S9