A vulnerability has been identified in COMOS V10.4.5 (All versions < V10.4.5.0.2), COMOS V10.6 (All versions < V10.6.1), Designcenter NX (Al
- Published
- Last modified
- Where the record stands: published, rejected by its publisher, or superseded by another id.What do these mean? →
- published
- Whether CISA lists it in its Known Exploited Vulnerabilities catalog: proof that attackers are using it.What do these mean? →
- Not listed in CISA KEV
- Fix
- Fixed in V10.4.5.0.2, V10.6.1, V2512.7000, V2506.0003, V2512.0002, and 8 more
- Whether working attack code is public (Exploit-DB, Metasploit, Nuclei or GitHub). Public code makes attacks easier.What do these mean? →
- None on Exploit-DB, Metasploit or GitHub
- Exploitation: none
- Automatable: no
- Technical impact: total
Summary
A vulnerability has been identified in COMOS V10.4.5 (All versions < V10.4.5.0.2), COMOS V10.6 (All versions < V10.6.1), Designcenter NX (All versions < V2512.7000), Simcenter 3D (All versions < V2512.7000), Simcenter Femap V2506 (All versions < V2506.0003), Simcenter Femap V2512 (All versions < V2512.0002), Simcenter Nastran (All versions < V2606), Simcenter STAR-CCM+ (All versions < V2606), Solid Edge SE2025 (All versions < V225.0 Update 13), Solid Edge SE2026 (All versions < V226.0 Update 04), Teamcenter Visualization V2412 (All versions < V2412.0012), Teamcenter Visualization V2506 (All versions < V2506.0009), Teamcenter Visualization V2512 (All versions < V2512.2605), Tecnomatix Plant Simulation V2404 (All versions < V2404.0022), Tecnomatix Plant Simulation V2504 (All versions < V2504.0010), Tecnomatix Process Simulate (All versions < V2606). Untrusted search path in IAM Client SDK may allow an authenticated user to potentially enable escalation of privilege via local access.
Timeline
- CVE published
- CISA SSVC assessment
Exploitation: none · Automatable: no · Technical impact: total
- Record last updated
Affected versions
- Siemens COMOS V10.4.5
fixed in V10.4.5.0.2
- Siemens COMOS V10.6
fixed in V10.6.1
- Siemens Designcenter NX
fixed in V2512.7000
- Siemens Simcenter 3D
fixed in V2512.7000
- Siemens Simcenter Femap V2506
fixed in V2506.0003
- Siemens Simcenter Femap V2512
fixed in V2512.0002
- Siemens Simcenter Nastran
fixed in V2606
- Siemens Simcenter STAR-CCM+
fixed in V2606
- Siemens Solid Edge SE2025
fixed in V225.0 Update 13
- Siemens Solid Edge SE2026
fixed in V226.0 Update 04
- Siemens Teamcenter Visualization V2412
fixed in V2412.0012
- Siemens Teamcenter Visualization V2506
fixed in V2506.0009
- Siemens Teamcenter Visualization V2512
fixed in V2512.2605
- Siemens Tecnomatix Plant Simulation V2404
fixed in V2404.0022
- Siemens Tecnomatix Plant Simulation V2504
fixed in V2504.0010
- Siemens Tecnomatix Process Simulate
fixed in V2606