CVE-2025-40569

A vulnerability has been identified in RUGGEDCOM RST2428P (6GK6242-6PA00) (All versions < V3.2), SCALANCE XCH328 (6GK5328-4TS01-2EC2) (All v

Published
Last modified
published
Not listed in CISA KEV
Fix
Fixed in V3.2
None on Exploit-DB, Metasploit or GitHub
  • Exploitation: none
  • Automatable: no
  • Technical impact: partial

Summary

A vulnerability has been identified in RUGGEDCOM RST2428P (6GK6242-6PA00) (All versions < V3.2), SCALANCE XCH328 (6GK5328-4TS01-2EC2) (All versions < V3.2), SCALANCE XCM324 (6GK5324-8TS01-2AC2) (All versions < V3.2), SCALANCE XCM328 (6GK5328-4TS01-2AC2) (All versions < V3.2), SCALANCE XCM332 (6GK5332-0GA01-2AC2) (All versions < V3.2), SCALANCE XRH334 (24 V DC, 8xFO, CC) (6GK5334-2TS01-2ER3) (All versions < V3.2), SCALANCE XRM334 (230 V AC, 12xFO) (6GK5334-3TS01-3AR3) (All versions < V3.2), SCALANCE XRM334 (230 V AC, 8xFO) (6GK5334-2TS01-3AR3) (All versions < V3.2), SCALANCE XRM334 (230V AC, 2x10G, 24xSFP, 8xSFP+) (6GK5334-5TS01-3AR3) (All versions < V3.2), SCALANCE XRM334 (24 V DC, 12xFO) (6GK5334-3TS01-2AR3) (All versions < V3.2), SCALANCE XRM334 (24 V DC, 8xFO) (6GK5334-2TS01-2AR3) (All versions < V3.2), SCALANCE XRM334 (24V DC, 2x10G, 24xSFP, 8xSFP+) (6GK5334-5TS01-2AR3) (All versions < V3.2), SCALANCE XRM334 (2x230 V AC, 12xFO) (6GK5334-3TS01-4AR3) (All versions < V3.2), SCALANCE XRM334 (2x230 V AC, 8xFO) (6GK5334-2TS01-4AR3) (All versions < V3.2), SCALANCE XRM334 (2x230V AC, 2x10G, 24xSFP, 8xSFP+) (6GK5334-5TS01-4AR3) (All versions < V3.2). The "Load Configuration from Local PC" functionality in the web interface of affected products contains a race condition vulnerability. This could allow an authenticated remote attacker to make the affected product load an attacker controlled configuration instead of the legitimate one. Successful exploitation requires that a legitimate administrator invokes the functionality and the attacker wins the race condition.

Timeline

  1. CVE published
  2. CISA SSVC assessment

    Exploitation: none · Automatable: no · Technical impact: partial

  3. Record last updated

Affected versions

  • Siemens RUGGEDCOM RST2428P

    fixed in V3.2

  • Siemens SCALANCE XCH328

    fixed in V3.2

  • Siemens SCALANCE XCM324

    fixed in V3.2

  • Siemens SCALANCE XCM328

    fixed in V3.2

  • Siemens SCALANCE XCM332

    fixed in V3.2

  • Siemens SCALANCE XRH334 (24 V DC, 8xFO, CC)

    fixed in V3.2

  • Siemens SCALANCE XRM334 (230 V AC, 12xFO)

    fixed in V3.2

  • Siemens SCALANCE XRM334 (230 V AC, 8xFO)

    fixed in V3.2

  • Siemens SCALANCE XRM334 (230V AC, 2x10G, 24xSFP, 8xSFP+)

    fixed in V3.2

  • Siemens SCALANCE XRM334 (24 V DC, 12xFO)

    fixed in V3.2

  • Siemens SCALANCE XRM334 (24 V DC, 8xFO)

    fixed in V3.2

  • Siemens SCALANCE XRM334 (24V DC, 2x10G, 24xSFP, 8xSFP+)

    fixed in V3.2

  • Siemens SCALANCE XRM334 (2x230 V AC, 12xFO)

    fixed in V3.2

  • Siemens SCALANCE XRM334 (2x230 V AC, 8xFO)

    fixed in V3.2

  • Siemens SCALANCE XRM334 (2x230V AC, 2x10G, 24xSFP, 8xSFP+)

    fixed in V3.2

References 1

cert-portal.siemens.com