CVE-2025-34129
LILIN DVR RCE via Malicious FTP/NTP Configuration
- Published
- Last modified
- Where the record stands: published, rejected by its publisher, or superseded by another id.What do these mean? →
- published
- Whether CISA lists it in its Known Exploited Vulnerabilities catalog: proof that attackers are using it.What do these mean? →
- Not listed in CISA KEV
- Fix
- Fixed in 2.0b60_20200207
- Whether working attack code is public (Exploit-DB, Metasploit, Nuclei or GitHub). Public code makes attacks easier.What do these mean? →
- None on Exploit-DB, Metasploit or GitHub
CISA's decision points: whether it is exploited, whether attacks can be automated, and how much control an attacker gets. Assessed (SSVC 2.0.3).What do these mean? →
- Exploitation: none
- Automatable: yes
- Technical impact: total
Summary
A command injection vulnerability exists in LILIN Digital Video Recorder (DVR) devices prior to firmware version 2.0b60_20200207 due to insufficient sanitization of the FTP and NTP Server fields in the service configuration. An attacker with access to the configuration interface can upload a malicious XML file with injected shell commands in these fields. Upon subsequent configuration syncs, these commands are executed with elevated privileges. This vulnerability was exploited in the wild by the Moobot botnets.
Timeline
- CVE published
- CISA SSVC assessment
Exploitation: none · Automatable: yes · Technical impact: total
- Record last updated
Affected versions
- Merit LILIN DVR Firmware
fixed in 2.0b60_20200207