Junos OS: SRX Series: Transmission of specific control traffic sent out of a DS-Lite tunnel results in flowd crash

Published
Last modified
published
Not listed in CISA KEV
Fix
Fixed in 21.2R3-S9, 21.4R3-S9, 22.2R3-S5, 22.4R3-S6, 23.2R2-S3, and 1 more
None on Exploit-DB, Metasploit or GitHub
  • Exploitation: none
  • Automatable: yes
  • Technical impact: partial

Summary

A NULL Pointer Dereference vulnerability in the flow daemon (flowd) of Juniper Networks Junos OS on SRX Series allows an attacker causing specific, valid control traffic to be sent out of a Dual-Stack (DS) Lite tunnel to crash the flowd process, resulting in a Denial of Service (DoS).  Continuous triggering of specific control traffic will create a sustained Denial of Service (DoS) condition. On all SRX platforms, when specific, valid control traffic needs to be sent out of a DS-Lite tunnel, a segmentation fault occurs within the flowd process, resulting in a network outage until the flowd process restarts. This issue affects Junos OS on SRX Series: • All versions before 21.2R3-S9, • from 21.4 before 21.4R3-S9, • from 22.2 before 22.2R3-S5, • from 22.4 before 22.4R3-S6, • from 23.2 before 23.2R2-S3, • from 23.4 before 23.4R2.

Timeline

  1. CVE published
  2. CISA SSVC assessment

    Exploitation: none · Automatable: yes · Technical impact: partial

  3. Record last updated

Affected versions

  • Juniper Networks Junos OS

    fixed in 21.2R3-S9; From 21.4 · fixed in 21.4R3-S9; From 22.2 · fixed in 22.2R3-S5; From 22.4 · fixed in 22.4R3-S6; From 23.2 · fixed in 23.2R2-S3; From 23.4 · fixed in 23.4R2