Skip to main content
← All vulnerabilities
CVE-2025-26793

The Web GUI configuration panel of Hirsch (formerly Identiv and Viscount) Enterphone MESH through 2024 ships with default credentials (usern

Published
Last modified
published
Not listed in CISA KEV
1 Nuclei template
  • Exploitation: none
  • Automatable: yes
  • Technical impact: partial

Summary

The Web GUI configuration panel of Hirsch (formerly Identiv and Viscount) Enterphone MESH through 2024 ships with default credentials (username freedom, password viscount). The administrator is not prompted to change these credentials on initial configuration, and changing the credentials requires many steps. Attackers can use the credentials over the Internet via mesh.webadmin.MESHAdminServlet to gain access to dozens of Canadian and U.S. apartment buildings and obtain building residents' PII. NOTE: the Supplier's perspective is that the "vulnerable systems are not following manufacturers' recommendations to change the default password."

Timeline

  1. CVE published
  2. CISA SSVC assessment

    Exploitation: none · Automatable: yes · Technical impact: partial

  3. Record last updated

Affected versions

  • Hirsch Enterphone MESH

    through 2024

References 4

support.identiv.com

ericdaigle.ca

news.ycombinator.com

GitHub · projectdiscovery/nuclei-templates