CVE-2025-25037
Aquatronica Controller System Complete Information Disclosure
- Published
- Last modified
- Where the record stands: published, rejected by its publisher, or superseded by another id.What do these mean? →
- published
- Whether CISA lists it in its Known Exploited Vulnerabilities catalog: proof that attackers are using it.What do these mean? →
- Not listed in CISA KEV
- Whether working attack code is public (Exploit-DB, Metasploit, Nuclei or GitHub). Public code makes attacks easier.What do these mean? →
- 1 Nuclei template
CISA's decision points: whether it is exploited, whether attacks can be automated, and how much control an attacker gets. Assessed (SSVC 2.0.3).What do these mean? →
- Exploitation: poc
- Automatable: no
- Technical impact: partial
Summary
An information disclosure vulnerability exists in Aquatronica Controller System firmware versions <= 5.1.6 and web interface versions <= 2.0. The tcp.php endpoint fails to restrict unauthenticated access, allowing remote attackers to issue crafted POST requests and retrieve sensitive configuration data, including plaintext administrative credentials. Exploitation of this flaw can lead to full compromise of the system, enabling unauthorized manipulation of connected devices and aquarium parameters.
Timeline
- CVE published
- CISA SSVC assessment
Exploitation: poc · Automatable: no · Technical impact: partial
- Record last updated
Affected versions
- Aquatronica Aquatronica Controller System
through 5.1.6