Skip to main content
← All vulnerabilities
CVE-2025-22961

A critical information disclosure vulnerability exists in the web-based management interface of GatesAir Maxiva UAXT, VAXT transmitters due

Published
Last modified
published
Not listed in CISA KEV
None on Exploit-DB, Metasploit or GitHub
  • Exploitation: poc
  • Automatable: no
  • Technical impact: total

Summary

A critical information disclosure vulnerability exists in the web-based management interface of GatesAir Maxiva UAXT, VAXT transmitters due to Incorrect Access Control (CWE-284). Unauthenticated attackers can directly access sensitive database backup files (snapshot_users.db) via publicly exposed URLs (/logs/devcfg/snapshot/ and /logs/devcfg/user/). Exploiting this vulnerability allows retrieval of sensitive user data, including login credentials, potentially leading to full system compromise.

Timeline

  1. CVE published
  2. CISA SSVC assessment

    Exploitation: poc · Automatable: no · Technical impact: total

  3. Record last updated

Affected versions

  • n/a n/a

    Version range not reported

References 1

GitHub · shiky8/my--cve-vulnerability-research