CVE-2025-22961
A critical information disclosure vulnerability exists in the web-based management interface of GatesAir Maxiva UAXT, VAXT transmitters due
- Published
- Last modified
- Where the record stands: published, rejected by its publisher, or superseded by another id.What do these mean? →
- published
- Whether CISA lists it in its Known Exploited Vulnerabilities catalog: proof that attackers are using it.What do these mean? →
- Not listed in CISA KEV
- Whether working attack code is public (Exploit-DB, Metasploit, Nuclei or GitHub). Public code makes attacks easier.What do these mean? →
- None on Exploit-DB, Metasploit or GitHub
CISA's decision points: whether it is exploited, whether attacks can be automated, and how much control an attacker gets. Assessed (SSVC 2.0.3).What do these mean? →
- Exploitation: poc
- Automatable: no
- Technical impact: total
Summary
A critical information disclosure vulnerability exists in the web-based management interface of GatesAir Maxiva UAXT, VAXT transmitters due to Incorrect Access Control (CWE-284). Unauthenticated attackers can directly access sensitive database backup files (snapshot_users.db) via publicly exposed URLs (/logs/devcfg/snapshot/ and /logs/devcfg/user/). Exploiting this vulnerability allows retrieval of sensitive user data, including login credentials, potentially leading to full system compromise.
Timeline
- CVE published
- CISA SSVC assessment
Exploitation: poc · Automatable: no · Technical impact: total
- Record last updated
Affected versions
- n/a n/a
Version range not reported