Skip to main content
← All vulnerabilities
CVE-2025-14858

Semtech LR11xx Encrypted Firmware Disclosure

Published
Last modified
published
Not listed in CISA KEV
Fix
Fixed in TRX FW 0x0402, TRX FW 0x0202, TRX FW 0x0104
None on Exploit-DB, Metasploit or GitHub
  • Exploitation: none
  • Automatable: no
  • Technical impact: total

Summary

The Semtech LR11xx LoRa transceivers running early versions of firmware contains an information disclosure vulnerability in its firmware validation functionality. When a host issues a firmware validity check command via the SPI interface, the device decrypts the provided encrypted firmware package block-by-block to validate its integrity. However, the last decrypted firmware block remains uncleared in memory after the validation process completes. An attacker with access to the SPI interface can subsequently issue memory read commands to retrieve the decrypted firmware contents from this residual memory, effectively bypassing the firmware encryption protection mechanism. The attack requires physical access to the device's SPI interface.

Timeline

  1. CVE published
  2. CISA SSVC assessment

    Exploitation: none · Automatable: no · Technical impact: total

  3. Record last updated

Affected versions

  • Semtech LR1110

    fixed in TRX FW 0x0402

  • Semtech LR1120

    fixed in TRX FW 0x0202

  • Semtech LR1121

    fixed in TRX FW 0x0104

References 1

semtech.com