Credentials exposure in tinycontrol devices
- Published
- Last modified
- Where the record stands: published, rejected by its publisher, or superseded by another id.What do these mean? →
- published
- Whether CISA lists it in its Known Exploited Vulnerabilities catalog: proof that attackers are using it.What do these mean? →
- Not listed in CISA KEV
- Fix
- Fixed in 1.67, 1.75, 1.38, 1.36
- Whether working attack code is public (Exploit-DB, Metasploit, Nuclei or GitHub). Public code makes attacks easier.What do these mean? →
- None on Exploit-DB, Metasploit or GitHub
- Exploitation: none
- Automatable: no
- Technical impact: total
Summary
Tinycontrol devices such as tcPDU and LAN Controllers LK3.5, LK3.9 and LK4 have two separate authentication mechanisms - one solely for interface management and one for protecting all other server resources. When the latter is turned off (which is a default setting), an unauthenticated attacker on the local network can obtain usernames and encoded passwords for interface management portal by inspecting the HTTP response of the server when visiting the login page, which contains a JSON file with these details. Both normal and admin users credentials are exposed. This issue has been fixed in firmware versions: 1.36 (for tcPDU), 1.67 (for LK3.5 - hardware versions: 3.5, 3.6, 3.7 and 3.8), 1.75 (for LK3.9 - hardware version 3.9) and 1.38 (for LK4 - hardware version 4.0).
Timeline
- CVE published
- CISA SSVC assessment
Exploitation: none · Automatable: no · Technical impact: total
- Record last updated
Affected versions
- tinycontrol Lan Kontroler v3.5
fixed in 1.67
- tinycontrol LK3.9
fixed in 1.75
- tinycontrol LK4
fixed in 1.38
- tinycontrol tcPDU