CVE-2024-10772
SICK InspectorP61x and SICK InspectorP62x are vulnerable for firmware modification
- Published
- Last modified
- Where the record stands: published, rejected by its publisher, or superseded by another id.What do these mean? →
- published
- Whether CISA lists it in its Known Exploited Vulnerabilities catalog: proof that attackers are using it.What do these mean? →
- Not listed in CISA KEV
- Fix
- Fixed in <5.0.0
- Whether working attack code is public (Exploit-DB, Metasploit, Nuclei or GitHub). Public code makes attacks easier.What do these mean? →
- None on Exploit-DB, Metasploit or GitHub
CISA's decision points: whether it is exploited, whether attacks can be automated, and how much control an attacker gets. Assessed (SSVC 2.0.3).What do these mean? →
- Exploitation: none
- Automatable: no
- Technical impact: total
Summary
Since the firmware update is not validated, an attacker can install modified firmware on the device. This has a high impact on the availabilty, integrity and confidentiality up to the complete compromise of the device.
Timeline
- CVE published
- CISA SSVC assessment
Exploitation: none · Automatable: no · Technical impact: total
- Record last updated
Affected versions
- SICK AG SICK InspectorP61x
fixed in <5.0.0
- SICK AG SICK InspectorP62x
fixed in <5.0.0