Skip to main content
← All vulnerabilities
CVE-2023-35920

A vulnerability has been identified in SIMATIC MV540 H (All versions < V3.3.4), SIMATIC MV540 S (All versions < V3.3.4), SIMATIC MV550 H (Al

Published
Last modified
published
Not listed in CISA KEV
None on Exploit-DB, Metasploit or GitHub
  • Exploitation: none
  • Automatable: yes
  • Technical impact: partial

Summary

A vulnerability has been identified in SIMATIC MV540 H (All versions < V3.3.4), SIMATIC MV540 S (All versions < V3.3.4), SIMATIC MV550 H (All versions < V3.3.4), SIMATIC MV550 S (All versions < V3.3.4), SIMATIC MV560 U (All versions < V3.3.4), SIMATIC MV560 X (All versions < V3.3.4). Affected devices cannot properly process specially crafted IP packets sent to the devices. This could allow an unauthenticated remote attacker to cause a denial of service condition. The affected devices must be restarted manually.

Timeline

  1. CVE published
  2. CISA SSVC assessment

    Exploitation: none · Automatable: yes · Technical impact: partial

  3. Record last updated

Affected versions

  • Siemens SIMATIC MV540 H

    All versions < V3.3.4

  • Siemens SIMATIC MV540 S

    All versions < V3.3.4

  • Siemens SIMATIC MV550 H

    All versions < V3.3.4

  • Siemens SIMATIC MV550 S

    All versions < V3.3.4

  • Siemens SIMATIC MV560 U

    All versions < V3.3.4

  • Siemens SIMATIC MV560 X

    All versions < V3.3.4

References 1

cert-portal.siemens.com