A vulnerability has been identified in SIPROTEC 5 6MD85 (CP300) (All versions >= V7.80 < V9.40), SIPROTEC 5 6MD86 (CP300) (All versions >= V

Published
Last modified
published
Not listed in CISA KEV
Fix
Fixed in V9.40, V9.64, V8.90, V8.89
None on Exploit-DB, Metasploit or GitHub

Summary

A vulnerability has been identified in SIPROTEC 5 6MD85 (CP300) (All versions >= V7.80 < V9.40), SIPROTEC 5 6MD86 (CP300) (All versions >= V7.80 < V9.40), SIPROTEC 5 6MD89 (CP300) (All versions >= V7.80 < V9.64), SIPROTEC 5 6MU85 (CP300) (All versions >= V7.80 < V9.40), SIPROTEC 5 7KE85 (CP300) (All versions >= V7.80 < V9.40), SIPROTEC 5 7SA82 (CP100) (All versions < V8.90), SIPROTEC 5 7SA82 (CP150) (All versions < V9.40), SIPROTEC 5 7SA86 (CP300) (All versions >= V7.80 < V9.40), SIPROTEC 5 7SA87 (CP300) (All versions >= V7.80 < V9.40), SIPROTEC 5 7SD82 (CP100) (All versions < V8.90), SIPROTEC 5 7SD82 (CP150) (All versions < V9.40), SIPROTEC 5 7SD86 (CP300) (All versions >= V7.80 < V9.40), SIPROTEC 5 7SD87 (CP300) (All versions >= V7.80 < V9.40), SIPROTEC 5 7SJ81 (CP100) (All versions < V8.89), SIPROTEC 5 7SJ81 (CP150) (All versions < V9.40), SIPROTEC 5 7SJ82 (CP100) (All versions < V8.89), SIPROTEC 5 7SJ82 (CP150) (All versions < V9.40), SIPROTEC 5 7SJ85 (CP300) (All versions >= V7.80 < V9.40), SIPROTEC 5 7SJ86 (CP300) (All versions >= V7.80 < V9.40), SIPROTEC 5 7SK82 (CP100) (All versions < V8.89), SIPROTEC 5 7SK82 (CP150) (All versions < V9.40), SIPROTEC 5 7SK85 (CP300) (All versions >= V7.80 < V9.40), SIPROTEC 5 7SL82 (CP100) (All versions < V8.90), SIPROTEC 5 7SL82 (CP150) (All versions < V9.40), SIPROTEC 5 7SL86 (CP300) (All versions >= V7.80 < V9.40), SIPROTEC 5 7SL87 (CP300) (All versions >= V7.80 < V9.40), SIPROTEC 5 7SS85 (CP300) (All versions >= V7.80 < V9.40), SIPROTEC 5 7ST85 (CP300) (All versions >= V7.80 < V9.64), SIPROTEC 5 7ST86 (CP300) (All versions >= V7.80 < V9.40), SIPROTEC 5 7SX82 (CP150) (All versions < V9.40), SIPROTEC 5 7SX85 (CP300) (All versions >= V7.80 < V9.40), SIPROTEC 5 7UM85 (CP300) (All versions >= V7.80 < V9.40), SIPROTEC 5 7UT82 (CP100) (All versions < V8.90), SIPROTEC 5 7UT82 (CP150) (All versions < V9.40), SIPROTEC 5 7UT85 (CP300) (All versions >= V7.80 < V9.40), SIPROTEC 5 7UT86 (CP300) (All versions >= V7.80 < V9.40), SIPROTEC 5 7UT87 (CP300) (All versions >= V7.80 < V9.40), SIPROTEC 5 7VE85 (CP300) (All versions >= V7.80 < V9.40), SIPROTEC 5 7VK87 (CP300) (All versions >= V7.80 < V9.40), SIPROTEC 5 7VU85 (CP300) (All versions >= V7.80 < V9.40), SIPROTEC 5 Communication Module ETH-BA-2EL (Rev.1) (All versions < V9.40 installed on CP150 and CP300 devices), SIPROTEC 5 Communication Module ETH-BA-2EL (Rev.1) (All versions < V8.89 installed on CP100 devices), SIPROTEC 5 Communication Module ETH-BB-2FO (Rev. 1) (All versions < V9.40 installed on CP150 and CP300 devices), SIPROTEC 5 Communication Module ETH-BB-2FO (Rev. 1) (All versions < V8.89 installed on CP100 devices), SIPROTEC 5 Communication Module ETH-BD-2FO (All versions < V9.40), SIPROTEC 5 Compact 7SX800 (CP050) (All versions < V9.40). Affected devices lack proper validation of http request parameters of the hosted web service. An unauthenticated remote attacker could send specially crafted packets that could cause denial of service condition of the target device.

Timeline

  1. CVE published
  2. Record last updated

Affected versions

  • Siemens SIPROTEC 5 6MD85 (CP300)

    From V7.80 · fixed in V9.40

  • Siemens SIPROTEC 5 6MD86 (CP300)

    From V7.80 · fixed in V9.40

  • Siemens SIPROTEC 5 6MD89 (CP300)

    From V7.80 · fixed in V9.64

  • Siemens SIPROTEC 5 6MU85 (CP300)

    From V7.80 · fixed in V9.40

  • Siemens SIPROTEC 5 7KE85 (CP300)

    From V7.80 · fixed in V9.40

  • Siemens SIPROTEC 5 7SA82 (CP100)

    fixed in V8.90

  • Siemens SIPROTEC 5 7SA82 (CP150)

    fixed in V9.40

  • Siemens SIPROTEC 5 7SA86 (CP300)

    From V7.80 · fixed in V9.40

  • Siemens SIPROTEC 5 7SA87 (CP300)

    From V7.80 · fixed in V9.40

  • Siemens SIPROTEC 5 7SD82 (CP100)

    fixed in V8.90

  • Siemens SIPROTEC 5 7SD82 (CP150)

    fixed in V9.40

  • Siemens SIPROTEC 5 7SD86 (CP300)

    From V7.80 · fixed in V9.40

  • Siemens SIPROTEC 5 7SD87 (CP300)

    From V7.80 · fixed in V9.40

  • Siemens SIPROTEC 5 7SJ81 (CP100)

    fixed in V8.89

  • Siemens SIPROTEC 5 7SJ81 (CP150)

    fixed in V9.40

  • Siemens SIPROTEC 5 7SJ82 (CP100)

    fixed in V8.89

  • Siemens SIPROTEC 5 7SJ82 (CP150)

    fixed in V9.40

  • Siemens SIPROTEC 5 7SJ85 (CP300)

    From V7.80 · fixed in V9.40

  • Siemens SIPROTEC 5 7SJ86 (CP300)

    From V7.80 · fixed in V9.40

  • Siemens SIPROTEC 5 7SK82 (CP100)

    fixed in V8.89

  • Siemens SIPROTEC 5 7SK82 (CP150)

    fixed in V9.40

  • Siemens SIPROTEC 5 7SK85 (CP300)

    From V7.80 · fixed in V9.40

  • Siemens SIPROTEC 5 7SL82 (CP100)

    fixed in V8.90

  • Siemens SIPROTEC 5 7SL82 (CP150)

    fixed in V9.40

  • Siemens SIPROTEC 5 7SL86 (CP300)

    From V7.80 · fixed in V9.40

  • Siemens SIPROTEC 5 7SL87 (CP300)

    From V7.80 · fixed in V9.40

  • Siemens SIPROTEC 5 7SS85 (CP300)

    From V7.80 · fixed in V9.40

  • Siemens SIPROTEC 5 7ST85 (CP300)

    From V7.80 · fixed in V9.64

  • Siemens SIPROTEC 5 7ST86 (CP300)

    From V7.80 · fixed in V9.40

  • Siemens SIPROTEC 5 7SX82 (CP150)

    fixed in V9.40

  • Siemens SIPROTEC 5 7SX85 (CP300)

    From V7.80 · fixed in V9.40

  • Siemens SIPROTEC 5 7UM85 (CP300)

    From V7.80 · fixed in V9.40

  • Siemens SIPROTEC 5 7UT82 (CP100)

    fixed in V8.90

  • Siemens SIPROTEC 5 7UT82 (CP150)

    fixed in V9.40

  • Siemens SIPROTEC 5 7UT85 (CP300)

    From V7.80 · fixed in V9.40

  • Siemens SIPROTEC 5 7UT86 (CP300)

    From V7.80 · fixed in V9.40

  • Siemens SIPROTEC 5 7UT87 (CP300)

    From V7.80 · fixed in V9.40

  • Siemens SIPROTEC 5 7VE85 (CP300)

    From V7.80 · fixed in V9.40

  • Siemens SIPROTEC 5 7VK87 (CP300)

    From V7.80 · fixed in V9.40

  • Siemens SIPROTEC 5 7VU85 (CP300)

    From V7.80 · fixed in V9.40

  • Siemens SIPROTEC 5 Communication Module ETH-BA-2EL (Rev.1)

    fixed in V9.40

  • Siemens SIPROTEC 5 Communication Module ETH-BA-2EL (Rev.1)

    fixed in V8.89

  • Siemens SIPROTEC 5 Communication Module ETH-BB-2FO (Rev. 1)

    fixed in V9.40

  • Siemens SIPROTEC 5 Communication Module ETH-BB-2FO (Rev. 1)

    fixed in V8.89

  • Siemens SIPROTEC 5 Communication Module ETH-BD-2FO

    fixed in V9.40

  • Siemens SIPROTEC 5 Compact 7SX800 (CP050)

    fixed in V9.40