Command Execution through Serial Interface of u-blox TOBY-L2
- Published
- Last modified
- Where the record stands: published, rejected by its publisher, or superseded by another id.What do these mean? →
- published
- Whether CISA lists it in its Known Exploited Vulnerabilities catalog: proof that attackers are using it.What do these mean? →
- Not listed in CISA KEV
- Whether working attack code is public (Exploit-DB, Metasploit, Nuclei or GitHub). Public code makes attacks easier.What do these mean? →
- None on Exploit-DB, Metasploit or GitHub
- Exploitation: none
- Automatable: no
- Technical impact: total
Summary
A flaw in the input validation in TOBY-L2 allows a user to execute arbitrary operating system commands using specifically crafted AT commands. This vulnerability requires physical access to the serial interface of the module or the ability to modify the system or software which uses its serial interface to send malicious AT commands. Exploitation of the vulnerability gives full administrative (root) privileges to the attacker to execute any operating system command on TOBY-L2 which can lead to modification of the behavior of the module itself as well as the components connected with it (depending on its rights on other connected systems). It can further provide the ability to read system level files and hamper the availability of the module as well.. This issue affects TOBY-L2 series: TOBY-L200, TOBY-L201, TOBY-L210, TOBY-L220, TOBY-L280.
Timeline
- CVE published
- CISA SSVC assessment
Exploitation: none · Automatable: no · Technical impact: total
- Record last updated
Affected versions
- u-blox TOBY-L2
TOBY-L200, TOBY-L201, TOBY-L210, TOBY-L220, TOBY-L280