CVE-2022-46832
Use of a Broken or Risky Cryptographic Algorithm in SICK RFU62x firmware version < 2.21 allows a low-privileged remote attacker to decrypt t
- Published
- Last modified
- Where the record stands: published, rejected by its publisher, or superseded by another id.What do these mean? →
- published
- Whether CISA lists it in its Known Exploited Vulnerabilities catalog: proof that attackers are using it.What do these mean? →
- Not listed in CISA KEV
- Fix
- Fixed in v2.21
- Whether working attack code is public (Exploit-DB, Metasploit, Nuclei or GitHub). Public code makes attacks easier.What do these mean? →
- None on Exploit-DB, Metasploit or GitHub
CISA's decision points: whether it is exploited, whether attacks can be automated, and how much control an attacker gets. Assessed (SSVC 2.0.3).What do these mean? →
- Exploitation: none
- Automatable: no
- Technical impact: partial
Summary
Use of a Broken or Risky Cryptographic Algorithm in SICK RFU62x firmware version < 2.21 allows a low-privileged remote attacker to decrypt the encrypted data if the user requested weak cipher suites to be used for encryption via the SSH interface. The patch and installation procedure for the firmware update is available from the responsible SICK customer contact person.
Timeline
- CVE published
- CISA SSVC assessment
Exploitation: none · Automatable: no · Technical impact: partial
- Record last updated
Affected versions
- n/a SICK RFU62x Firmware
fixed in v2.21