CVE-2022-45790
Omron FINS memory protection susceptible to bruteforce
- Published
- Last modified
- Where the record stands: published, rejected by its publisher, or superseded by another id.What do these mean? →
- published
- Whether CISA lists it in its Known Exploited Vulnerabilities catalog: proof that attackers are using it.What do these mean? →
- Not listed in CISA KEV
- Fix
- Fixed in 1.5, 2.1, 4.1, 1.4, 1.3
- Whether working attack code is public (Exploit-DB, Metasploit, Nuclei or GitHub). Public code makes attacks easier.What do these mean? →
- None on Exploit-DB, Metasploit or GitHub
CISA's decision points: whether it is exploited, whether attacks can be automated, and how much control an attacker gets. Assessed (SSVC 2.0.3).What do these mean? →
- Exploitation: none
- Automatable: yes
- Technical impact: partial
Summary
The Omron FINS protocol has an authenticated feature to prevent access to memory regions. Authentication is susceptible to bruteforce attack, which may allow an adversary to gain access to protected memory. This access can allow overwrite of values including programmed logic.
Timeline
- CVE published
- CISA SSVC assessment
Exploitation: none · Automatable: yes · Technical impact: partial
- Record last updated
Affected versions
- Omron CJ-series and CS-series CPU modules
From CJ2H 0.0 · fixed in 1.5; From CJ2M 0.0 · fixed in 2.1; From CJ1G 0.0 · fixed in 4.1; From CS1H 0.0 · fixed in 4.1; From CS1G 0.0 · fixed in 4.1; From CS1D-H 0.0 · fixed in 1.4; From CP1E-E 0.0 · fixed in 1.3; From CP1E-N 0.0 · fixed in 1.3; From CS1D-P 0.0 · fixed in 1.4