Junos OS: MX Series and SRX Series: The flowd daemon will crash if the SIP ALG is enabled and specific SIP messages are processed
- Published
- Last modified
- Where the record stands: published, rejected by its publisher, or superseded by another id.What do these mean? →
- published
- Whether CISA lists it in its Known Exploited Vulnerabilities catalog: proof that attackers are using it.What do these mean? →
- Not listed in CISA KEV
- Fix
- Fixed in 20.4R3-S1
- Whether working attack code is public (Exploit-DB, Metasploit, Nuclei or GitHub). Public code makes attacks easier.What do these mean? →
- None on Exploit-DB, Metasploit or GitHub
Summary
An Improper Locking vulnerability in the SIP ALG of Juniper Networks Junos OS on MX Series and SRX Series allows an unauthenticated networked attacker to cause a flowprocessing daemon (flowd) crash and thereby a Denial of Service (DoS). Continued receipt of these specific packets will cause a sustained Denial of Service condition. This issue can occur in a scenario where the SIP ALG is enabled and specific SIP messages are being processed simultaneously. This issue affects: Juniper Networks Junos OS on MX Series and SRX Series 20.4 versions prior to 20.4R3-S1; 21.1 versions prior to 21.1R2-S2, 21.1R3; 21.2 versions prior to 21.2R1-S2, 21.2R2; 21.3 versions prior to 21.3R1-S1, 21.3R2. This issue does not affect Juniper Networks Junos OS versions prior to 20.4R1.
Timeline
- CVE published
- Record last updated
Affected versions
- Juniper Networks Junos OS
From 20.4 · fixed in 20.4R3-S1