Skip to main content
← All vulnerabilities
CVE-2022-1669

Circutor COMPACT DC-S BASIC

Published
Last modified
published
Not listed in CISA KEV
None on Exploit-DB, Metasploit or GitHub
  • Exploitation: none
  • Automatable: no
  • Technical impact: partial

Summary

A buffer overflow vulnerability has been detected in the firewall function of the device management web portal. The device runs a CGI binary (index.cgi) to offer a management web application. Once authenticated with valid credentials in this web portal, a potential attacker could submit any "Address" value and it would be copied to a second variable with a "strcpy" vulnerable function without checking its length. Because of this, it is possible to send a long address value to overflow the process stack, controlling the function return address.

Timeline

  1. CVE published
  2. CISA SSVC assessment

    Exploitation: none · Automatable: no · Technical impact: partial

  3. Record last updated

Affected versions

  • CIRCUTOR COMPACT DC-S BASIC

    CIR_CDC_v1.2.17

References 1

cisa.gov