Skip to main content
← All vulnerabilities
CVE-2022-1368

Cognex 3D-A1000 Dimensioning System Missing Authentication for Critical Function

Published
Last modified
published
Not listed in CISA KEV
None on Exploit-DB, Metasploit or GitHub
  • Exploitation: none
  • Automatable: yes
  • Technical impact: total

Summary

The Cognex 3D-A1000 Dimensioning System in firmware version 1.0.3 (3354) and prior is vulnerable to CWE-306: Missing Authentication for Critical Function, which allows unauthorized users to change the operator account password via webserver commands by monitoring web socket communications from an unauthenticated session. This could allow an attacker to escalate privileges to match those of the compromised account.

Timeline

  1. CVE published
  2. CISA SSVC assessment

    Exploitation: none · Automatable: yes · Technical impact: total

  3. Record last updated

Affected versions

  • Cognex 3D-A1000 Dimensioning System

    through 1.0.3 (3354)

References 1

cisa.gov