Skip to main content
← All vulnerabilities
CVE-2021-31345

A vulnerability has been identified in Capital Embedded AR Classic 431-422 (All versions), Capital Embedded AR Classic R20-11 (All versions

Published
Last modified
published
Not listed in CISA KEV
Fix
Fixed in V2303
None on Exploit-DB, Metasploit or GitHub

Summary

A vulnerability has been identified in Capital Embedded AR Classic 431-422 (All versions), Capital Embedded AR Classic R20-11 (All versions < V2303), PLUSCONTROL 1st Gen (All versions). The total length of an UDP payload (set in the IP header) is unchecked. This may lead to various side effects, including Information Leak and Denial-of-Service conditions, depending on a user-defined applications that runs on top of the UDP protocol. (FSMD-2021-0006)

Timeline

  1. CVE published
  2. Record last updated

Affected versions

  • Siemens Capital Embedded AR Classic 431-422

    All versions

  • Siemens Capital Embedded AR Classic R20-11

    fixed in V2303

  • Siemens PLUSCONTROL 1st Gen

    All versions

References 8

cert-portal.siemens.com