Skip to main content
← All vulnerabilities
CVE-2021-25664

A vulnerability has been identified in Capital Embedded AR Classic 431-422 (All versions), Capital Embedded AR Classic R20-11 (All versions

Published
Last modified
published
Not listed in CISA KEV
Fix
Fixed in V2303, V2017.02.4, V4.1.0
None on Exploit-DB, Metasploit or GitHub

Summary

A vulnerability has been identified in Capital Embedded AR Classic 431-422 (All versions), Capital Embedded AR Classic R20-11 (All versions < V2303), Nucleus NET (All versions), Nucleus ReadyStart V3 (All versions < V2017.02.4), Nucleus ReadyStart V4 (All versions < V4.1.0), Nucleus Source Code (All versions including affected IPv6 stack). The function that processes the Hop-by-Hop extension header in IPv6 packets and its options lacks any checks against the length field of the header, allowing attackers to put the function into an infinite loop by supplying arbitrary length values.

Timeline

  1. CVE published
  2. Record last updated

Affected versions

  • Siemens Capital Embedded AR Classic 431-422

    All versions

  • Siemens Capital Embedded AR Classic R20-11

    fixed in V2303

  • Siemens Nucleus NET

    All versions

  • Siemens Nucleus ReadyStart V3

    fixed in V2017.02.4

  • Siemens Nucleus ReadyStart V4

    fixed in V4.1.0

  • Siemens Nucleus Source Code

    All versions

References 3

cert-portal.siemens.com

us-cert.cisa.gov