Skip to main content
← All vulnerabilities
CVE-2020-28391

A vulnerability has been identified in SCALANCE X-200 switch family (incl.

Published
Last modified
published
Not listed in CISA KEV
None on Exploit-DB, Metasploit or GitHub

Summary

A vulnerability has been identified in SCALANCE X-200 switch family (incl. SIPLUS NET variants) (All versions < V5.2.5), SCALANCE X-200IRT switch family (incl. SIPLUS NET variants) (All versions < V5.5.0), SCALANCE X-200RNA switch family (All versions < V3.2.7). Devices create a new unique key upon factory reset, except when used with C-PLUG. When used with C-PLUG the devices use the hardcoded private RSA-key shipped with the firmware-image. An attacker could leverage this situation to a man-in-the-middle situation and decrypt previously captured traffic.

Timeline

  1. CVE published
  2. Record last updated

Affected versions

  • Siemens SCALANCE X-200 switch family (incl. SIPLUS NET variants)

    All versions < V5.2.5

  • Siemens SCALANCE X-200IRT switch family (incl. SIPLUS NET variants)

    All versions < V5.5.0

  • Siemens SCALANCE X-200RNA switch family

    All versions < V3.2.7

References 2

cert-portal.siemens.com

us-cert.cisa.gov