CVE-2019-20461
An issue was discovered on Alecto IVM-100 2019-11-12 devices.
- Published
- Last modified
- Where the record stands: published, rejected by its publisher, or superseded by another id.What do these mean? →
- published
- Whether CISA lists it in its Known Exploited Vulnerabilities catalog: proof that attackers are using it.What do these mean? →
- Not listed in CISA KEV
- Whether working attack code is public (Exploit-DB, Metasploit, Nuclei or GitHub). Public code makes attacks easier.What do these mean? →
- None on Exploit-DB, Metasploit or GitHub
CISA's decision points: whether it is exploited, whether attacks can be automated, and how much control an attacker gets. Assessed (SSVC 2.0.3).What do these mean? →
- Exploitation: none
- Automatable: yes
- Technical impact: total
Summary
An issue was discovered on Alecto IVM-100 2019-11-12 devices. The device uses a custom UDP protocol to start and control video and audio services. The protocol has been partially reverse engineered. Based upon the reverse engineering, no password or username is ever transferred over this protocol. Thus, one can set up the camera connection feed with only the encoded UID. It is possible to set up sessions with the camera over the Internet by using the encoded UID and the custom UDP protocol, because authentication happens at the client side.
Timeline
- CVE published
- CISA SSVC assessment
Exploitation: none · Automatable: yes · Technical impact: total
- Record last updated
Affected versions
- n/a n/a
Version range not reported