CVE-2018-25141
FLIR Thermal Traffic Cameras V1.01-0bb5b27 Unauthenticated RTSP Stream Disclosure
- Published
- Last modified
- Where the record stands: published, rejected by its publisher, or superseded by another id.What do these mean? →
- published
- Whether CISA lists it in its Known Exploited Vulnerabilities catalog: proof that attackers are using it.What do these mean? →
- Not listed in CISA KEV
- Whether working attack code is public (Exploit-DB, Metasploit, Nuclei or GitHub). Public code makes attacks easier.What do these mean? →
- None on Exploit-DB, Metasploit or GitHub
CISA's decision points: whether it is exploited, whether attacks can be automated, and how much control an attacker gets. Assessed (SSVC 2.0.3).What do these mean? →
- Exploitation: poc
- Automatable: yes
- Technical impact: partial
Summary
FLIR thermal traffic cameras contain an unauthenticated vulnerability that allows remote attackers to access live video streams without credentials. Attackers can directly retrieve video streams by accessing specific endpoints like /live.mjpeg, /snapshot.jpg, and RTSP streaming URLs without authentication.
Timeline
- CVE published
- CISA SSVC assessment
Exploitation: poc · Automatable: yes · Technical impact: partial
- Record last updated
Affected versions
- FLIR FLIR Thermal Traffic Cameras
1.01-0bb5b27