Applications developed using the Portrait Display SDK, versions 2.30 through 2.34, default to insecure configurations which allow arbitrary code execution

Published
Last modified
published
Not listed in CISA KEV
None on Exploit-DB, Metasploit or GitHub

Summary

Applications developed using the Portrait Display SDK, versions 2.30 through 2.34, default to insecure configurations which allow arbitrary code execution. A number of applications developed using the Portrait Displays SDK do not use secure permissions when running. These applications run the component pdiservice.exe with NT AUTHORITY/SYSTEM permissions. This component is also read/writable by all Authenticated Users. This allows local authenticated attackers to run arbitrary code with SYSTEM privileges. The following applications have been identified by Portrait Displays as affected: Fujitsu DisplayView Click: Version 6.0 and 6.01. The issue was fixed in Version 6.3. Fujitsu DisplayView Click Suite: Version 5. The issue is addressed by patch in Version 5.9. HP Display Assistant: Version 2.1. The issue was fixed in Version 2.11. HP My Display: Version 2.0. The issue was fixed in Version 2.1. Philips Smart Control Premium: Versions 2.23, 2.25. The issue was fixed in Version 2.26.

Timeline

  1. CVE published
  2. Record last updated

Affected versions

  • Portrait Display SDK

    From 2.30

References 2

securityfocus.com