CVE-2013-10058
Linksys Routers apply.cgi Remote Command Injection
- Published
- Last modified
- Where the record stands: published, rejected by its publisher, or superseded by another id.What do these mean? →
- published
- Whether CISA lists it in its Known Exploited Vulnerabilities catalog: proof that attackers are using it.What do these mean? →
- Not listed in CISA KEV
- Whether working attack code is public (Exploit-DB, Metasploit, Nuclei or GitHub). Public code makes attacks easier.What do these mean? →
- 1 Metasploit module
CISA's decision points: whether it is exploited, whether attacks can be automated, and how much control an attacker gets. Assessed (SSVC 2.0.3).What do these mean? →
- Exploitation: poc
- Automatable: yes
- Technical impact: total
Summary
An authenticated OS command injection vulnerability exists in various Linksys router models (tested on WRT160Nv2) running firmware version v2.0.03 via the apply.cgi endpoint. The web interface fails to properly sanitize user-supplied input passed to the ping_size parameter during diagnostic operations. An attacker with valid credentials can inject arbitrary shell commands, enabling remote code execution.
Timeline
- CVE published
- CISA SSVC assessment
Exploitation: poc · Automatable: yes · Technical impact: total
- Record last updated
Affected versions
- Linksys WRT160nv2
2.0.03