Skip to main content
← All vulnerabilities
CVE-2011-4879

miniweb.exe in the HMI web server in Siemens WinCC flexible 2004, 2005, 2007, and 2008 before SP3; WinCC V11 (aka TIA portal) before SP2 Upd

Published
Last modified
published
Not listed in CISA KEV
1 on Exploit-DB

Summary

miniweb.exe in the HMI web server in Siemens WinCC flexible 2004, 2005, 2007, and 2008 before SP3; WinCC V11 (aka TIA portal) before SP2 Update 1; the TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime Advanced; and WinCC flexible Runtime does not properly handle URIs beginning with a 0xfa character, which allows remote attackers to read data from arbitrary memory locations or cause a denial of service (application crash) via a crafted POST request.

Timeline

  1. Public exploit on Exploit-DB

    EDB-18166

  2. CVE published
  3. Record last updated
  4. EPSS reached 10%

    FIRST estimates at least a 10% chance of exploitation in the next 30 days

Affected versions

  • n/a n/a

    Version range not reported

References 9

us-cert.gov

siemens.com

Exploit-DB

aluigi.org

osvdb.org